UPS and Battery Backup Glossary

Short, precise definitions of the terms you will meet on UPS spec sheets, battery labels and software settings, each linked to the guide that explains it in depth.

A

Active PFC
Active power factor correction: circuitry in a power supply that shapes input current into a near-sine wave, giving a power factor around 0.95 to 0.99. Some active-PFC supplies misbehave on simulated sine wave UPS output. Learn more
Amp-hour (Ah)
A battery's charge capacity: the current it can deliver for a stated time, normally specified at the 20-hour rate for VRLA batteries. Multiply by voltage to get watt-hours. Learn more
apcupsd
An open-source daemon for monitoring APC UPS units and shutting down computers on low battery. Learn more
Apparent power
Volts multiplied by amps (VA). It can exceed real power when current is out of phase with voltage or distorted. Learn more
AVR (automatic voltage regulation)
A line-interactive feature that boosts low voltage or trims high voltage with transformer taps, without using the battery. Learn more

B

Battery-backed outlet
A UPS outlet that receives power from the inverter during an outage, as opposed to a surge-only outlet. Learn more
Blackout
A complete loss of utility power, from a fraction of a second to days. Learn more
Boost and trim
The two AVR actions: boost raises low input voltage, trim lowers high input voltage. Learn more
Brownout
A sustained period of low voltage, sometimes deliberate when a utility reduces voltage under heavy demand. Learn more
Bypass
A path that feeds the load directly from utility power, skipping the UPS electronics, used during faults or maintenance. Learn more

C

C13 / C14
IEC 60320 connectors common on computers, servers and rack UPS outlets. C13 is the cord end, C14 the equipment inlet. Learn more
C19 / C20
Larger IEC 60320 connectors for high-current servers and PDUs. Learn more
Clamping voltage
The voltage at which a surge protector begins diverting surge energy. Lower is generally better; see VPR for the standardized rating. Learn more
Cold start
Starting a UPS on battery power when no utility power is present. Learn more
Connected equipment guarantee
A manufacturer's promise to cover damage to equipment plugged into its UPS or surge protector under stated conditions. Learn more
Crest factor
The ratio of peak current to RMS current. Non-PFC power supplies have high crest factors that stress UPS inverters. Learn more

D

DC mini UPS
A small battery unit that outputs DC (often 5, 9, 12 or 24 V) directly to devices like routers, avoiding inverter losses. Learn more
Design life
The battery maker's expected life under ideal conditions, usually at 25 °C. Real service life is shorter. Learn more
Double conversion
The online UPS method: AC is rectified to DC and inverted back to clean AC continuously. Learn more

E

Eco mode
A high-efficiency mode on some online UPS units that passes utility power through and switches to the inverter only when needed. Learn more
Extended battery module (EBM)
An external battery pack that connects to a compatible UPS to extend runtime. Learn more

F

F1 / F2 terminal
Flat quick-connect battery terminals, 0.187 in and 0.250 in wide respectively. Learn more
Float charge
The low, constant voltage that keeps a fully charged lead-acid battery topped up. Learn more
Frequency variation
Departure from the nominal 60 Hz or 50 Hz, common with generators. Only online UPS units correct it. Learn more

G

Graceful shutdown
An orderly, automatic shutdown of computers triggered by UPS software before the battery runs out. Learn more

H

Harmonics
Currents or voltages at multiples of the fundamental frequency, created by nonlinear loads. Learn more
HID (USB)
Human Interface Device class: the standard USB protocol most UPS units use to report status to operating systems. Learn more
High-rate battery
A VRLA block designed for short, heavy discharges, often rated in watts per cell over 15 minutes. Learn more
Hold-up time
How long a power supply keeps its output in regulation after input power disappears, typically around 16 ms or more for computer PSUs. Learn more

I

Inverter
The UPS circuit that converts battery DC into AC output. Learn more

J

Joule rating
A surge protector's energy absorption figure. Useful as a rough durability indicator, not a measure of protection quality. Learn more

L

LiFePO4
Lithium iron phosphate, a lithium battery chemistry with long cycle and calendar life used in newer UPS units and power stations. Learn more
Line-interactive UPS
A UPS that passes utility power through an autotransformer with AVR, switching to battery only when the input is out of range. Learn more
Load percentage
The share of a UPS's watt rating your equipment uses. Learn more

M

MCOV
Maximum continuous operating voltage: the highest voltage a surge protector can withstand continuously. Learn more

N

NEMA 5-15
The standard North American 125 V, 15 A plug and receptacle. Learn more
Network management card
An add-in card that gives a UPS its own network interface for web, SNMP and shutdown signaling. Learn more
NUT (Network UPS Tools)
Open-source software that monitors many UPS brands and coordinates shutdown across multiple machines. Learn more

O

Online UPS
A UPS whose inverter supplies the load at all times (double conversion), giving zero transfer time. Learn more
Overload
A load above the UPS rating. The UPS alarms and may shut off its output on battery. Learn more

P

PDU
Power distribution unit: a rack power strip, optionally metered or switched. Learn more
Peukert effect
The reduction in a battery's usable capacity at high discharge rates, pronounced in lead-acid batteries. Learn more
Power conditioner
A device that filters noise and may regulate voltage, without battery backup. Learn more
Power factor
Real power divided by apparent power (W / VA). Learn more
Power station (portable)
A portable battery with inverter and outlets, typically lithium, designed for long runtime rather than seamless switchover. Learn more
Pure sine wave
Inverter output that closely matches a utility sine wave. Learn more

R

Real power
Power actually consumed, in watts. Learn more
Runtime
How long a UPS can support a given load on battery. Learn more

S

Sag
A short drop in voltage lasting from a fraction of a cycle to about a minute, often caused by large loads starting. Learn more
Self-test
A brief automatic or manual transfer to battery used to check battery health. Learn more
Sensitivity setting
A UPS option that sets how strictly it judges input power before switching to battery. Learn more
Simulated sine wave
A stepped approximation of a sine wave (also called modified or stepped sine) used by lower-cost inverters. Learn more
Site wiring fault
A UPS indication of missing ground or reversed hot and neutral at the outlet. Learn more
SNMP
Simple Network Management Protocol, used by network management cards to report UPS status to monitoring systems. Learn more
SPD (surge protective device)
The code term for surge protectors. Type 1 and 2 install at the service or panel; Type 3 at the point of use. Learn more
Spike (transient)
A very short, high-voltage event lasting microseconds to milliseconds, from switching or lightning. Learn more
Standby UPS
Also called offline: passes utility power through and switches to battery on failure. Simplest and cheapest design. Learn more
Surge-only outlet
A UPS outlet with surge protection but no battery backup. Learn more
Swell
A short rise in voltage above normal. Learn more

T

THD (total harmonic distortion)
A measure of how far a waveform departs from a pure sine wave, expressed in percent. Learn more
Transfer time
The gap between utility failure and battery power reaching the load in standby and line-interactive UPS units. Learn more

U

UL 1449
The UL safety standard for surge protective devices, which defines the VPR rating. Learn more
UL 1778
The UL safety standard for uninterruptible power supply equipment. Learn more

V

VA (volt-ampere)
The unit of apparent power. Learn more
VPR (voltage protection rating)
A standardized UL 1449 rating of the voltage let through by a surge protector during a test surge. Lower is better. Learn more
VRLA battery
Valve-regulated lead-acid: the sealed AGM or gel batteries used in most UPS units. Learn more

W

Watt-hour (Wh)
A unit of energy: one watt for one hour. Battery Wh = volts x amp-hours. Learn more