UPS and Battery Backup Glossary
Short, precise definitions of the terms you will meet on UPS spec sheets, battery labels and software settings, each linked to the guide that explains it in depth.
A
- Active PFC
- Active power factor correction: circuitry in a power supply that shapes input current into a near-sine wave, giving a power factor around 0.95 to 0.99. Some active-PFC supplies misbehave on simulated sine wave UPS output. Learn more
- Amp-hour (Ah)
- A battery's charge capacity: the current it can deliver for a stated time, normally specified at the 20-hour rate for VRLA batteries. Multiply by voltage to get watt-hours. Learn more
- apcupsd
- An open-source daemon for monitoring APC UPS units and shutting down computers on low battery. Learn more
- Apparent power
- Volts multiplied by amps (VA). It can exceed real power when current is out of phase with voltage or distorted. Learn more
- AVR (automatic voltage regulation)
- A line-interactive feature that boosts low voltage or trims high voltage with transformer taps, without using the battery. Learn more
B
- Battery-backed outlet
- A UPS outlet that receives power from the inverter during an outage, as opposed to a surge-only outlet. Learn more
- Blackout
- A complete loss of utility power, from a fraction of a second to days. Learn more
- Boost and trim
- The two AVR actions: boost raises low input voltage, trim lowers high input voltage. Learn more
- Brownout
- A sustained period of low voltage, sometimes deliberate when a utility reduces voltage under heavy demand. Learn more
- Bypass
- A path that feeds the load directly from utility power, skipping the UPS electronics, used during faults or maintenance. Learn more
C
- C13 / C14
- IEC 60320 connectors common on computers, servers and rack UPS outlets. C13 is the cord end, C14 the equipment inlet. Learn more
- C19 / C20
- Larger IEC 60320 connectors for high-current servers and PDUs. Learn more
- Clamping voltage
- The voltage at which a surge protector begins diverting surge energy. Lower is generally better; see VPR for the standardized rating. Learn more
- Cold start
- Starting a UPS on battery power when no utility power is present. Learn more
- Connected equipment guarantee
- A manufacturer's promise to cover damage to equipment plugged into its UPS or surge protector under stated conditions. Learn more
- Crest factor
- The ratio of peak current to RMS current. Non-PFC power supplies have high crest factors that stress UPS inverters. Learn more
D
- DC mini UPS
- A small battery unit that outputs DC (often 5, 9, 12 or 24 V) directly to devices like routers, avoiding inverter losses. Learn more
- Design life
- The battery maker's expected life under ideal conditions, usually at 25 °C. Real service life is shorter. Learn more
- Double conversion
- The online UPS method: AC is rectified to DC and inverted back to clean AC continuously. Learn more
E
- Eco mode
- A high-efficiency mode on some online UPS units that passes utility power through and switches to the inverter only when needed. Learn more
- Extended battery module (EBM)
- An external battery pack that connects to a compatible UPS to extend runtime. Learn more
F
- F1 / F2 terminal
- Flat quick-connect battery terminals, 0.187 in and 0.250 in wide respectively. Learn more
- Float charge
- The low, constant voltage that keeps a fully charged lead-acid battery topped up. Learn more
- Frequency variation
- Departure from the nominal 60 Hz or 50 Hz, common with generators. Only online UPS units correct it. Learn more
G
- Graceful shutdown
- An orderly, automatic shutdown of computers triggered by UPS software before the battery runs out. Learn more
H
- Harmonics
- Currents or voltages at multiples of the fundamental frequency, created by nonlinear loads. Learn more
- HID (USB)
- Human Interface Device class: the standard USB protocol most UPS units use to report status to operating systems. Learn more
- High-rate battery
- A VRLA block designed for short, heavy discharges, often rated in watts per cell over 15 minutes. Learn more
- Hold-up time
- How long a power supply keeps its output in regulation after input power disappears, typically around 16 ms or more for computer PSUs. Learn more
I
- Inverter
- The UPS circuit that converts battery DC into AC output. Learn more
J
- Joule rating
- A surge protector's energy absorption figure. Useful as a rough durability indicator, not a measure of protection quality. Learn more
L
- LiFePO4
- Lithium iron phosphate, a lithium battery chemistry with long cycle and calendar life used in newer UPS units and power stations. Learn more
- Line-interactive UPS
- A UPS that passes utility power through an autotransformer with AVR, switching to battery only when the input is out of range. Learn more
- Load percentage
- The share of a UPS's watt rating your equipment uses. Learn more
M
- MCOV
- Maximum continuous operating voltage: the highest voltage a surge protector can withstand continuously. Learn more
N
- NEMA 5-15
- The standard North American 125 V, 15 A plug and receptacle. Learn more
- Network management card
- An add-in card that gives a UPS its own network interface for web, SNMP and shutdown signaling. Learn more
- NUT (Network UPS Tools)
- Open-source software that monitors many UPS brands and coordinates shutdown across multiple machines. Learn more
O
- Online UPS
- A UPS whose inverter supplies the load at all times (double conversion), giving zero transfer time. Learn more
- Overload
- A load above the UPS rating. The UPS alarms and may shut off its output on battery. Learn more
P
- PDU
- Power distribution unit: a rack power strip, optionally metered or switched. Learn more
- Peukert effect
- The reduction in a battery's usable capacity at high discharge rates, pronounced in lead-acid batteries. Learn more
- Power conditioner
- A device that filters noise and may regulate voltage, without battery backup. Learn more
- Power factor
- Real power divided by apparent power (W / VA). Learn more
- Power station (portable)
- A portable battery with inverter and outlets, typically lithium, designed for long runtime rather than seamless switchover. Learn more
- Pure sine wave
- Inverter output that closely matches a utility sine wave. Learn more
R
- Real power
- Power actually consumed, in watts. Learn more
- Runtime
- How long a UPS can support a given load on battery. Learn more
S
- Sag
- A short drop in voltage lasting from a fraction of a cycle to about a minute, often caused by large loads starting. Learn more
- Self-test
- A brief automatic or manual transfer to battery used to check battery health. Learn more
- Sensitivity setting
- A UPS option that sets how strictly it judges input power before switching to battery. Learn more
- Simulated sine wave
- A stepped approximation of a sine wave (also called modified or stepped sine) used by lower-cost inverters. Learn more
- Site wiring fault
- A UPS indication of missing ground or reversed hot and neutral at the outlet. Learn more
- SNMP
- Simple Network Management Protocol, used by network management cards to report UPS status to monitoring systems. Learn more
- SPD (surge protective device)
- The code term for surge protectors. Type 1 and 2 install at the service or panel; Type 3 at the point of use. Learn more
- Spike (transient)
- A very short, high-voltage event lasting microseconds to milliseconds, from switching or lightning. Learn more
- Standby UPS
- Also called offline: passes utility power through and switches to battery on failure. Simplest and cheapest design. Learn more
- Surge-only outlet
- A UPS outlet with surge protection but no battery backup. Learn more
- Swell
- A short rise in voltage above normal. Learn more
T
- THD (total harmonic distortion)
- A measure of how far a waveform departs from a pure sine wave, expressed in percent. Learn more
- Transfer time
- The gap between utility failure and battery power reaching the load in standby and line-interactive UPS units. Learn more
U
- UL 1449
- The UL safety standard for surge protective devices, which defines the VPR rating. Learn more
- UL 1778
- The UL safety standard for uninterruptible power supply equipment. Learn more
V
- VA (volt-ampere)
- The unit of apparent power. Learn more
- VPR (voltage protection rating)
- A standardized UL 1449 rating of the voltage let through by a surge protector during a test surge. Lower is better. Learn more
- VRLA battery
- Valve-regulated lead-acid: the sealed AGM or gel batteries used in most UPS units. Learn more
W
- Watt-hour (Wh)
- A unit of energy: one watt for one hour. Battery Wh = volts x amp-hours. Learn more