UniFi UPS Shutdown: UDM, UNVR and UNAS on Power Failure

A UniFi UPS (Tower, 2U or 2U Pro) shuts down a UNVR or UNAS by itself, with UniFi OS 4.4.3 or later. A Dream Machine or other gateway is not on Ubiquiti's list. Everything else, such as a Synology, TrueNAS or Proxmox box, follows the UPS through its built-in NUT server on port 3493.

On this page
  1. What a UniFi UPS shuts down by itself
  2. The three UniFi UPS models side by side
  3. Worked through: a 300 W closet on a Tower
  4. Pointing NUT clients at a UniFi UPS
  5. What to do with the Dream Machine
  6. Tower or a 1500 VA CyberPower
  7. What this page does not cover
  8. Frequently asked questions

What a UniFi UPS shuts down by itself

Ubiquiti sells three UPS units under the UniFi name. All three product pages say the same thing: they support "Graceful Shutdown for UNVR and UNAS," plus "NUT compatibility for third-party devices." Graceful Shutdown needs UniFi OS 4.4.3 or later. The 2U Pro also needs UniFi OS 5.1.25 or later to work at all.

A graceful shutdown is the opposite of a power cut. The device is told the battery is running out. It stops its services, finishes its disk writes and powers off on its own. When the battery dies a minute later, nothing is lost. Without that signal, the UPS only delays the crash.

So a UNVR (the UniFi video recorder) or a UNAS (the UniFi storage box) on a UniFi UPS needs no extra software. A Dream Machine, Cloud Gateway or other UniFi gateway is a different case. It is not on the list. Neither the store pages nor Ubiquiti's Power Redundancy help article describes a shutdown path for gateways. That article says a UniFi UPS gives "time for utility power to recover or equipment to shut down safely." It does not say which equipment the UPS will shut down.

The three UniFi UPS models side by side

These figures come from the technical tables on each US store page. Runtime is Ubiquiti's own figure at the load named.

UniFi UPS models (US versions), from Ubiquiti's spec tables
ModelRatingBatteryRuntime, half loadRuntime, full loadBattery waveformPlug
UPS Tower1,000 VA / 600 Wone 12 V 9 Ah (108 Wh)7 min at 300 W2 minSimulated sineNEMA 5-15P
UPS 2U1,440 VA / 1,000 Wtwo 12 V 9 Ah (216 Wh)8 min at 500 W2.3 minSimulated sineNEMA 5-15P
UPS 2U Pro1,920 VA / 1,920 W72 V 10 Ah (720 Wh)22 min at 960 W9 minPure sineNEMA 5-20P

Two rows need a second look. The Tower and the 2U both list a "simulated sine wave (battery mode)." Our waveform guide explains why some active PFC power supplies shut off on that output. And the 2U Pro uses a 20 A plug, so it needs a NEMA 5-20 receptacle, not an ordinary 15 A outlet.

Worked through: a 300 W closet on a Tower

Take a small closet like this one. A UDM Pro, a PoE switch with a few access points, a UNVR and a Synology NAS all sit on one UPS. Suppose a plug-in meter reads 300 W at the wall. That is a made-up load for the walkthrough. Measure your own with the steps in how to measure power draw.

On a UPS Tower, 300 W is exactly the half-load point. Ubiquiti's figure is 7 minutes. That is the whole budget, with a new battery at room temperature.

Now set the two NAS boxes against that clock. The UNVR follows the UPS through Graceful Shutdown. The Synology follows it through NUT. If the Synology waits for the low battery signal, it starts late. Ubiquiti's pages do not say at what charge or runtime the UniFi UPS raises that signal. A 7 minute battery does not leave room to find out during a real outage.

So give the Synology a fixed timer instead: 1 minute on battery, then Safe Mode. That leaves about 6 minutes of battery for it to finish. The UDM, switch and access points keep running until the battery is flat. When power returns, everything boots again.

Now run the same 300 W on a UPS 2U. Ubiquiti's 8 minutes at 500 W means the battery delivered about 67 Wh (500 W x 8/60 h). Straight scaling to 300 W gives about 13 minutes. Our runtime explainer shows that lead-acid gives up more energy at lighter loads, so the real figure is likely a little longer. Treat it as an estimate, not a spec.

Our rule of thumb: under 10 minutes, never wait for low battery

If the UPS's own half-load figure is under 10 minutes at your load, set every NUT client to a fixed on-battery timer of 1 to 2 minutes. Most outages are either a few seconds or much longer than the battery. A short timer rides out the first kind and gets ahead of the second. Waiting for low battery only makes sense when you have tested how much runtime is left when the signal arrives.

Pointing NUT clients at a UniFi UPS

Network UPS Tools (NUT) is the open-source standard that most NAS and Linux systems use to watch a UPS. Usually one computer holds the UPS's USB cable and runs the NUT server. A UniFi UPS skips that step. It reports over its own Ethernet port, so the UPS itself is the NUT server. Clients connect to its IP on TCP port 3493.

On the UPS

  1. Give the UPS a fixed address. Use a DHCP reservation or static IP. Every client stores this address, so it must not change.
  2. Turn on the NUT server. Owners describe the switch under UniFi Devices, then the UPS, then Settings. There you enable NUT Server and set login credentials. Labels can move between UniFi Network releases.
  3. Note the ID/Hostname. That field is the UPS name clients ask for, as in name@ip. One Home Assistant owner set it to the UPS's IP address. For a Synology, set it to ups.

Synology

In DSM, open Control Panel, Hardware & Power, UPS. Enable UPS support, choose Synology UPS server, and enter the UPS's IP. DSM gives you no fields for a UPS name, user or password. It assumes ups, monuser and secret. The Sierra Softworks write-up sets the UniFi side to exactly those values. Then pick the fixed time option for Safe Mode. Our Synology UPS guide covers the rest of DSM's settings.

TrueNAS and Unraid

In TrueNAS, set the UPS Mode to Slave (Secondary in newer wording). Enter the UPS's IP as the remote host. Then type the ID/Hostname, user and password you set on the UPS. Choose the shutdown mode UPS goes on battery with a short timer. The field-by-field table is in our TrueNAS guide. KW Systems documents the same pattern for Unraid on a UPS Tower. Their NUT plugin is set to Slave mode, pointed at the UPS's IP and port 3493, with the UniFi login.

Proxmox and other Linux hosts

Install the client only (apt install nut-client), set MODE=netclient, and add one line to upsmon.conf:

# /etc/nut/upsmon.conf on the client
# ups = the ID/Hostname set on the UniFi UPS
MONITOR ups@192.168.1.50 1 monuser secret secondary
SHUTDOWNCMD "/sbin/shutdown -h +0"

Test it before you rely on it: upsc ups@192.168.1.50 should print ups.status: OL. Owners on the Home Assistant forum report that the UPS rejects requests from a client that has not logged in. So if upsc fails, check the login and the name first.

A plain secondary only shuts down when the UPS reports low battery, or when the server orders a forced shutdown. That is the late trigger the worked example warns about. On a hypervisor, add an upssched timer so the host leaves after a minute or two on battery. The full config is in Proxmox UPS shutdown.

What to do with the Dream Machine

Keep the gateway on a battery outlet, and plan for it to run until the battery is flat. That is the right default for a gateway, not a workaround. If your NAS and the UPS sit on different VLANs, the NUT traffic between them is routed through the gateway. Shut the gateway down early and the clients lose their warning.

Some owners still want a clean stop. In a feature request for a NUT client, commenters point to the recording drive in a UDM running Protect. One community script shows the usual method. A Proxmox host runs the NUT client. On a power event, it logs in to the UDM Pro over SSH and runs ubnt-systool poweroff. That works only with SSH turned on and a stored key or password on the client. It relies on a command Ubiquiti does not document for this use. Run it last, after every other client has finished.

Tower or a 1500 VA CyberPower

The UPS Tower and a 1500 VA tower such as the CyberPower CP1500PFCLCD sell into the same closet. They are not built for the same job.

UniFi UPS Tower vs CyberPower CP1500PFCLCD, from each maker's spec sheet
UniFi UPS TowerCyberPower CP1500PFCLCD
Rating1,000 VA / 600 W1,500 VA / 1,000 W
Batteryone 12 V 9 Ah (108 Wh)two 12 V 9 Ah (216 Wh)
Half-load runtime7 min at 300 W10 min at 500 W
Full-load runtime2 min2.5 min
Battery waveformSimulated sineSine wave
How it reportsEthernet, built-in NUT serverUSB, so a host must run the NUT server
UNVR and UNAS shutdownYes, native (UniFi OS 4.4.3+)Not documented by Ubiquiti

Run the 300 W closet on the CyberPower. 10 minutes at 500 W is about 83 Wh delivered. Straight scaling to 300 W gives roughly 17 minutes, more than twice the Tower's 7. The cost is the data path. The CyberPower reports over USB, so a host has to run the NUT server, and that host must shut down last. See the NUT guide for that layout.

Bottom line

Choose the Tower if a UNVR or UNAS is the box you most need to protect and the load stays well under 300 W. Choose a 1500 VA sine wave unit if runtime matters more, or if a third-party NAS or server shares the battery. Near 500 W, the 2U is already at its 8 minute half-load point, and the 2U Pro gives 22 minutes at 960 W. For bigger racks, see UPS for a network rack.

What this page does not cover

Ubiquiti's pages do not give the low battery threshold. They do not say whether the UPS cuts and restores its own outlets after a shutdown, which decides whether halted devices boot by themselves when power returns. Owner reports about the NUT server also differ between firmware releases. Check your own UPS's settings page, then prove the setup by pulling the UPS plug from the wall at a quiet time. The figures here are for the 120 V US models. Other regions sell different versions with their own spec sheets. And nothing here covers the drive inside a UDM or a UNVR beyond what Graceful Shutdown already does. For camera recorders in general, see UPS for security cameras and an NVR.

Frequently asked questions

Does a UniFi UPS shut down a Dream Machine Pro?

Not according to Ubiquiti's product pages, which list Graceful Shutdown for UNVR and UNAS only. Keep the UDM on a battery outlet so the network stays up while other devices shut down. Some owners run a script on a NUT client that logs in to the UDM over SSH and powers it off. Ubiquiti does not document that method.

What username and password does the UniFi UPS NUT server use?

The ones you set in the UPS's NUT server settings. Most clients let you type any name and password, so match them. A Synology is the exception: DSM only asks for an IP, so set the ID/Hostname to ups, the user to monuser and the password to secret.

How long does a UniFi UPS Tower run?

Ubiquiti quotes 7 minutes at half load (300 W) and 2 minutes at full load (600 W), from one 12 V 9 Ah lead-acid battery (108 Wh). A small closet drawing 100 W runs longer. The battery also loses capacity with age, so plan shutdowns around the first few minutes.

Is the UniFi UPS Tower pure sine wave?

No. Ubiquiti's spec table gives a simulated sine wave in battery mode for both the Tower and the UPS 2U. Only the UPS 2U Pro lists a pure sine wave. If a third-party NAS or server with an active PFC power supply sits on a Tower, test it on battery before you rely on it.

Can Home Assistant read a UniFi UPS?

Yes, through its NUT integration pointed at the UPS's IP on port 3493. Owners on the Home Assistant forum report that the UPS rejects requests until the client logs in. One fixed it by setting a static IP and using that IP as the ID/Hostname. Another said a UPS firmware update fixed it.

Sources and further reading

  1. Ubiquiti Store: UniFi UPS Tower (UPS-Tower-US) overview and technical specifications
  2. Ubiquiti Store: UniFi UPS 2U (UPS-2U-US) overview and technical specifications
  3. Ubiquiti Store: UniFi UPS 2U Pro (UPS-2U-Pro-US) overview and technical specifications
  4. Ubiquiti Help Center: Power Redundancy
  5. CyberPower CP1500PFCLCD specifications
  6. Sierra Softworks: Pairing your Synology NAS with a UniFi UPS (August 2026)
  7. KW Systems: Unraid safe shutdown with a UniFi UPS
  8. Home Assistant Community: UniFi UPS Tower and NUT server
  9. Community gist: UPS shutdown scripts for a UDM Pro, run from a Proxmox NUT client
  10. unifios-utilities issue 528: feature request for a NUT client on UniFi OS (closed July 2026)
  11. Network UPS Tools User Manual