A laser job interrupted by a power cut is usually scrap: the material is half cut and the machine has forgotten the job. A UPS prevents that only if it carries the laser's peak draw, on a clean waveform, together with the fan that pulls the smoke out. Most failed attempts size to the wrong number.
What happens when the power goes out
In a 2017 Glowforge forum thread an owner wrote: "Power goes out and the GF stops immediately where ever it was. No lights, no movement. Everything resets when the power comes back on. The unit goes through a full calibration and waits for a new job." In a 2018 thread a Glowforge staff member confirmed the machine restarts, and the owner reported a later job about half an inch out of alignment after the recalibration.
Resume is not on offer. Dan Shapiro, Glowforge's CEO, wrote in 2016: "If you yank the power, it won't be an easy resume I'm afraid." In 2022 a Glowforge staff reply to an owner who lost power mid-passthrough said "it isn't possible to resume the Pro Passthrough print where it stopped."
None of the xTool P3, P2S, S1, F1 or M1 pages cited here describes resuming a job after power loss either. For both brands, plan as if a power cut ends the job. A 3D printer at least has firmware power-loss recovery; see UPS for a 3D printer.
Peak or average: which number sizes the UPS
Two figures circulate for a Glowforge, and both are real. Glowforge's spec page lists "800W peak power consumption" for the Basic, Plus and Pro. Owners quote about 300 W: a 2017 forum post put it as "800w peak and avg ~300w when running (per the FAQ on the main page)."
The peak is the one that sizes a UPS. An inverter does not average: if the load exceeds its rating, even briefly, it shuts off on battery, which ends the job exactly as a power cut would. Shapiro said the peak "will generally not be seen for a sustained period," which is why a UPS sized to the average can run fine for weeks and then fail mid-cut. The average sets the runtime.
A third set of figures adds confusion. Glowforge Support asks for "at least 800 watts of power available" and a breaker of "at least 15 amps" for the Performance Series, and "at least 300 watts" and "at least 5 amps" for the Aura. These describe the circuit, not the machine. The Aura's own product page gives "84W peak power consumption", well under the 300 W it asks you to have available.
Our analysis: the 1,600 W figure is a forum number, and 1,150 W is the documented one
The same 2017 thread says a Glowforge and its filter "draw about 1600 watts combined." Glowforge's spec page gives 800 W peak for the laser and 350 W peak for the Air Filter, which adds to 1,150 W. We use 1,150 W: it comes from the maker and is already a worst case, both peaks at once. Sizing to 1,600 W does no harm, but pushes you toward a UPS class that needs a 30 A twist-lock receptacle.
Glowforge and xTool power figures
Each figure is from the maker's own page. The labels differ: a peak or maximum consumption is what to size to, while an adapter rating is the brick's output ceiling, and wall draw sits a little above it.
| Machine | Laser | Published figure | What the figure is | Pure sine UPS, 80% ceiling |
|---|---|---|---|---|
| Glowforge Basic, Plus | 40 W CO2 | 800 W | Peak power consumption | 1,000 W |
| Glowforge Pro | 45 W CO2 | 800 W | Peak power consumption | 1,000 W |
| Glowforge Air Filter | n/a | 350 W | Peak power consumption | 440 W |
| Glowforge Basic, Plus or Pro with Air Filter | CO2 | 1,150 W | Sum of the two peaks | 1,440 W |
| Glowforge Aura | 6 W diode | 84 W | Peak power consumption | 105 W |
| xTool P3 | 80 W CO2 | 1,400 W | Maximum power consumption | 1,750 W |
| xTool P2S | 55 W CO2 | 700 W | Max. machine input power | 875 W |
| xTool S1 40W | 40 W diode | 275 W | Adapter output, 25 V 11 A | 345 W, plus margin |
| xTool S1 20W | 20 W diode | 192 W | Adapter output, 24 V 8 A | 240 W, plus margin |
| xTool M1 10W | 10 W diode | 121.5 W | Machine power | 152 W |
| xTool F1 | Diode and infrared | 120 W | Adapter, 24 V 5 A | 150 W, plus margin |
The last column divides the published figure by 0.8, the planning limit our guide to sizing a UPS uses for measured peaks. The Compact Filter is not on Glowforge's spec page; read its label. Glowforge specifies a "110/220 VAC, 50 or 60 HZ outlet" and xTool gives the P3 100 to 240 V AC, so the same watts apply on 230 V.
The exhaust fan and air assist go on battery too
A laser cutting on battery while its fan sits on a dead outlet is worse than a laser that simply stopped. The smoke has nowhere to go, and the air assist stops blowing at the cut while the beam keeps firing. If the job runs on battery, everything it needs runs on battery: the machine, the exhaust fan or filter, and the air assist pump.
Where those parts live varies. The P2S has a "built-in 145CFM exhaust fan", so its 700 W figure is the machine as a whole, and the Aura uses a "Custom laser head fan for combined cooling and air assist." The Glowforge Air Filter is a separate 350 W box, and many diode setups add an inline fan and air pump with their own plugs. Meter each external piece and add its watts; measuring power draw covers how.
Why pure sine
Glowforge has said what it tested. Asked about UPS units in 2016, Shapiro wrote "We've run them with true sine wave UPSs but nothing else," and three days later, "We've only tested with true sine wave, not simulated." Neither maker's pages cited here approve a stepped waveform, which also troubles active PFC power supplies and fan motors; pure sine vs simulated sine explains why. Buy the waveform the maker tested.
Which UPS for which machine
| Setup | Peak | UPS class | Peak load |
|---|---|---|---|
| Glowforge Aura, xTool F1 or M1 | 84 to 152 W, plus accessories | Pure sine 1500 VA / 1,000 W, or smaller pure sine | 8 to 15%, plus accessories |
| xTool S1 40W | 275 W, plus accessories | Pure sine 1500 VA / 1,000 W | 28%, plus accessories |
| xTool P2S | 700 W | Pure sine 1500 VA / 1,000 W (APC SMT1500C) | 70% |
| Glowforge Basic, Plus or Pro alone | 800 W | Pure sine 1,000 W is the bare minimum; 1,350 W or more is comfortable | 80% / 59% |
| Glowforge Basic, Plus or Pro with Air Filter | 1,150 W | Pure sine 2200 VA class (APC SMT2200C, 1,920 W) | 60% |
| xTool P3 | 1,400 W, plus any external fan | Pure sine 2200 VA class (1,920 W) | 73% |
APC lists the SMT1500C as "1440VA/1000W line interactive pure sine wave tower UPS" and the SMT2200C as "1920VA/1920W", with NEMA 5-20R outlets among its eight. The diode rows use adapter ratings, so add your measured fan and pump watts before choosing. A desktop 1500 VA unit rated 900 W puts a Glowforge's 800 W peak at 89%, over the limit, and units in that bracket are sold with both stepped and pure sine outputs, so that common purchase can fail twice. If the alarm does sound under load, UPS overload alarm walks through the causes.
Watch the circuit too. A 1,920 W UPS at full rating draws 16 A at 120 V, which is more than a 15 A circuit is meant to carry, and Glowforge's own minimum for the Performance Series is a 15 A breaker. A 2200 VA class unit belongs on a 20 A circuit, ideally a dedicated one.
How long the battery carries the job
These estimates use the model behind our UPS runtime calculator: new sealed lead-acid batteries, a Peukert exponent of 1.25 referenced to the 20-hour rating, 88% inverter efficiency and 8 W of inverter overhead. Battery sets are typical per class. Read the column nearest your average draw.
| UPS class (battery) | 120 W | 300 W | 700 W | 1,150 W |
|---|---|---|---|---|
| 1500 VA / 1,000 W (2 x 12 V 9 Ah) | 47 min | 16 min | 5 min | over rating |
| 1500 VA / 1,350 W (4 x 12 V 7 Ah) | 81 min | 27 min | 9 min | 5 min |
| 2200 VA / 1,650 to 1,980 W (2 x 12 V 18 Ah) | 1 h 51 min | 37 min | 13 min | 7 min |
| 3000 VA / 2,700 W (4 x 12 V 18 Ah) | 4 h 23 min | 88 min | 31 min | 17 min |
Here is the 300 W column on a 2200 VA class unit, the Glowforge's quoted average:
The 1,150 W column holds both Glowforge peaks continuously, so a real job with the filter lands between it and the 300 W column. UPS runtime explained covers why minutes fall faster than load rises.
Our rule of thumb: compare runtime to the time left on the job
With no resume, the battery has one task: outlast the rest of the job. Compare the time remaining against your runtime row. If it falls short, the UPS still covers short outages, but a long one costs the job either way. Size up, or split long jobs so less is lost.
Where this stops applying
- The figures are the makers' published ones. Newer revisions, the Compact Filter and third-party fans are not covered; read their labels.
- The runtime table assumes new batteries. A lead-acid UPS a few years old may give well under these minutes.
- The resume findings come from forum posts and the pages cited, not a maker statement; check your own model's manual.
An embroidery machine resumes, so a short bridge to stop cleanly is enough there. A laser does not, so the battery must carry the job to the end. If you need hours rather than minutes, compare a portable power station, checking its switchover time first.
Frequently asked questions
Will a laser cutter resume after a power outage?
Not a Glowforge. Owners report it stops, runs a full calibration when power returns and waits for a new job, and Glowforge staff have confirmed a job interrupted by power loss cannot be resumed where it stopped. None of the xTool spec and FAQ pages cited here documents a resume after power loss either. Plan as if the job is lost.
Why does Glowforge say 800 W and a 15 A breaker if it averages 300 W?
800 W is the peak the machine can draw, and a circuit or UPS has to supply the peak or it trips. The 300 W figure is a forum average while running. The 15 A breaker is a circuit requirement, not the draw: 800 W at 120 V is about 6.7 A, which leaves room for whatever else shares the circuit.
Can I put the exhaust fan on the surge-only outlets?
No. Surge-only outlets go dead in an outage. If the laser keeps firing on battery while the fan and air assist stop, smoke stays in the bed and the flame-suppressing airflow at the cut is gone. Either everything the job needs is on battery outlets, or the job should not run on battery at all.
Is a 1500 VA UPS enough for a Glowforge?
It depends which 1500 VA. A 1500 VA unit rated 900 W puts an 800 W peak at 89%, over the 80% planning limit, and units in that bracket are sold with stepped as well as pure sine outputs. A pure sine 1500 VA rated 1,000 W, such as APC's SMT1500C, puts it at exactly 80% with nothing else connected. Add the 350 W Air Filter and you need a 2,000 W class unit.
Can I use a portable power station instead?
For a small diode laser such as an xTool F1 (24 V 5 A adapter), a large power station with pure sine output holds far more energy than a desktop UPS. The catch is the handover: unless the station switches over fast enough when the grid fails, the laser resets and the job is lost anyway. Check its switchover time first; UPS vs portable power station covers what to look for.
Sources and further reading
- Glowforge Support: Won't turn on / no power (power available and breaker requirements)
- Glowforge Tech Specs (Basic, Plus, Pro and Air Filter peak power) and Glowforge Aura product page
- Glowforge Community threads: Loss of power and/or Internet (2016, Dan Shapiro), Power outage (2017), Power failure (2018), I lost electric in the middle of a pass through project (2022)
- xTool P3 FAQ; xTool P2S product page
- xTool S1 User Guide; xTool F1 Series FAQs; xTool M1 FAQ
- Schneider Electric (APC): SMT1500C and SMT2200C product pages