On this page
A CNC router is a computer-controlled machine that moves a spinning cutter along a toolpath. Stepper motors drive the gantry. The cutter turns in a trim router or a spindle, a motor built for the job and run by a VFD (variable frequency drive) that sets its speed. When the power blinks, all of that stops at once, with the bit still in the wood.
A UPS fixes the blink. For a longer outage it buys something smaller and still worth having: time for a feed hold. Feed hold is the controller's pause. The axes slow to a stop on the toolpath, the controller keeps its position, and the job can carry on from there. With the machine held, you lift the bit clear and switch the router off. That is the plan this page sizes for.
What happens when a CNC loses power
The controller resets. "If the controller loses power it will essentially reset itself back to first boot," a Onefinity owner wrote in 2021. Another confirmed the machine then asks to home and "won't move until instructed." The router coasts to a stop in the cut. The job, the position and the work zero all have to be rebuilt by hand.
Carbide Motion, the program Shapeoko owners use to send a job to the machine, now helps with the last step. Its 644 beta, posted in March 2025, added Program Restart, which lets you "start the program on almost any line." Before going on, it changes tools and moves to the start position for that line. But it does not record where a job died. Rob Grzesek of Carbide 3D said "tracking the last line executed" is something the team wants to add. For now, the line number shows when you pause, not after a power cut.
That is the whole case for a UPS here. A held job has a known line, a known position and a bit out of the work. A job killed by an outage has none of the three.
The router is the load, not the machine
The motion side of a hobby CNC draws little. Carbide 3D's docs say the Shapeoko and Nomad use "switching power supplies that work on either 110V or 220V." In 2018 William Adams of Carbide 3D put the machine's motors at "an estimated 300 watts." Onefinity's official requirements give its controller a maximum AC input of about 3.44 A at full load, or about 410 VA at 120 V. Both are ceilings, not what the motors draw on a typical pass.
The cutter draws several times that. Each figure below is from the maker, or from the maker's staff where the product page gives none.
| Cutter | Supply | Published draw | About | Source |
|---|---|---|---|---|
| Carbide Compact Router | 120 V | 6.5 A | 780 VA | Carbide 3D staff, 2018 (not on the product page) |
| Makita RT0701C (Onefinity's stock router) | 120 V | 6.5 A | 780 VA | Makita; Onefinity's requirements post |
| Carbide 65 mm VFD spindle, 1,200 W | 110 V | 12 A | 1,320 VA | Carbide 3D product page and docs |
| Carbide 80 mm VFD spindle, 2.2 kW | 220 V | 12 A | 2,640 VA | Carbide 3D; "cannot run on 110V" |
| Avid 3 HP spindle / VFD | 200 to 240 V | 8 A at peak | 1,920 VA | Avid CNC, L6-30 plug |
| Avid 4 HP spindle / VFD | 200 to 240 V | 11 A at peak | 2,640 VA | Avid CNC, L6-30 plug |
| Avid AV40S spindle / VFD | 200 to 240 V | 13.5 A at peak | 3,240 VA | Avid CNC, L6-30 plug |
The "About" column is amps times volts (240 V for the Avid rows). Two notes on the figures. Carbide 3D's current product page lists the Compact Router's speeds but no amps, so the 6.5 A is the staff figure from 2018. Makita's page also lists a soft start for the RT0701C, which ramps the motor up gently. That helps a UPS, because the router does not jolt it at switch-on.
Our analysis: why "my 1000 VA unit runs it fine" and the nameplate both hold
In a 2018 Carbide 3D thread, an owner ran a DeWalt router on an APC 1000 VA unit. The load meter "rarely" went past 2 of 5 lights, and 3 to 4 at startup. A router cutting a light pass draws well under its nameplate, so that is believable. The trouble is the deep pass or the plunge that does pull the full 6.5 A. A UPS that overloads on battery shuts off, which ends the job exactly as the outage would. Size to the nameplate. Time the battery on the lighter real draw.
Everything the job needs goes on battery, or nothing does
The worst setup is the half-measure. Put the controller on a UPS and the router on the wall, and in an outage the machine keeps going while the bit stops turning. Owners on the Carbide 3D and Onefinity forums give the same warning: the gantry drags a dead bit through the part. On the Onefinity forum it was put plainly: if only the controller has backup power, the part is destroyed.
So three things share the battery outlets:
- The machine's controller and motor supply. It holds position and carries out the feed hold.
- The router, or the spindle's VFD. It keeps cutting until you lift out.
- The PC or laptop running the job. On a Shapeoko the job streams from the computer one line at a time. If the PC dies, the job stops. A desktop PC dies the instant the wall power does. A laptop has its own battery, but count its charger anyway so it stays charged through the hold. A Onefinity runs the job from its own controller, so its touch screen goes on the UPS too.
The dust collector stays on the wall. Onefinity puts a typical shop vac at about 8 A, more than the router, and it can wait. A water chiller for a water-cooled spindle does go on battery: Carbide lists its CW3000 at 1 A at 110 V, and says the chiller "should always be turned on before running the spindle."
Worked example: a Shapeoko with a Compact Router
Take a Shapeoko 4 with a Carbide Compact Router, driven by a laptop running Carbide Motion. Suppose the laptop's charger is rated 65 W. Add the nameplate figures:
Treat the router's 780 VA as watts. A loaded brushed motor is close to that, and it errs high. Divide by 0.8, the planning ceiling in our guide to sizing a UPS:
APC lists the SMT1500C at "1440VA/1000W," so it is too small at 115% of its rating. The SMT2200C is rated "1920VA/1920W," which puts this load at 60%. That is the class to buy.
Now the battery. Work it through the model behind our UPS runtime calculator. A 2200 VA class unit with 2 x 12 V 18 Ah batteries gives about 7 minutes at the full 1,145 W. At a lighter 500 W it gives about 20 minutes. A feed hold, a lift and a router switch-off take well under a minute. Seven minutes also bridges most blinks and short cuts without stopping at all.
Suppose the outage runs past two minutes. Press pause, note the line number Carbide Motion shows, raise Z clear of the work and switch the router off. Then shut the machine down before the battery runs low. When power returns, home the machine, restore your work zero, and use Program Restart from that line.
Which UPS for which setup
Each row adds the cutter's published draw to the machine figure above. The peak load column divides that total by the UPS watt rating.
| Setup | Nameplate load | UPS class | Peak load | Runtime at nameplate |
|---|---|---|---|---|
| Shapeoko, Compact Router, laptop | 1,145 W | 2200 VA / 1,920 W (APC SMT2200C) | 60% | about 7 min |
| Onefinity with Makita RT0701C | about 1,190 W | 2200 VA / 1,920 W (APC SMT2200C) | 62% | about 7 min |
| Shapeoko, 65 mm VFD spindle, laptop | 1,685 W | 3000 VA / 2,700 W (APC SMT3000C) | 62% | about 10 min |
| Any 220 or 240 V spindle (Carbide 80 mm, Avid) | 1,920 VA and up | No 120 V UPS; a 240 V UPS sized to the VFD, or a planned stop | n/a | n/a |
The Onefinity row uses its 410 VA controller ceiling and no PC. The 65 mm VFD row is 88% of a 1,920 W unit, over the 80% ceiling, so it moves up a class. The runtime column uses the same model as above, with the 3000 VA class on 4 x 12 V 18 Ah batteries.
Check the circuit as well as the UPS. At 120 V, a 1,920 W UPS at full load draws 16 A and a 2,700 W one draws 22.5 A. The first belongs on a 20 A circuit. The second is past one, so read the SMT3000C's input plug and rating before you buy. Onefinity's own advice is to put the router on a different circuit from the controller. With both on one UPS, give that UPS a circuit of its own.
The 240 V spindles
Carbide's 80 mm spindle ships with an L6-20 plug and "requires a 220V outlet." Avid's spindle systems all take 200 to 240 V on an L6-30 plug. No 120 V desktop UPS can run them. A 240 V UPS sized to the VFD's peak can, but at 1,920 to 3,240 VA that is a large purchase for a minute of grace.
The cheaper plan is to let the spindle and machine stop together. A VFD spindle coasts down rather than stopping dead, which a LinuxCNC user counted on. That user planned to put only the PC and the stepper supply on a UPS. A power-loss signal would then trip the e-stop (emergency stop) and disable the drives, so the machine "would 'stop'" while keeping its place. That is a wiring project, not a plug-in setup. Without that signal, keep the controller off the UPS, for the reason above.
Why pure sine
A stepped-wave UPS is the wrong match here. The router's motor, a VFD's input stage and many PC power supplies with active PFC are the loads stepped output suits worst; pure sine vs simulated sine explains why. No CNC maker cited here approves a stepped wave. The 2200 and 3000 VA classes a router setup needs are sold in pure sine, so there is no reason to save money on the waveform.
The switchover itself is rarely the problem. The 2018 owner on the APC 1000 VA unit reported that "the UPS quickly switches over to battery and my SO3 kept on cutting just fine." UPS transfer time covers what that switch involves.
When power comes back
A router whose switch was left on starts the moment power returns. If it is plugged into the wall, or a UPS that shut down, it can spin up with your hands near the bit. A Onefinity forum member suggested a magnetic no-voltage-release switch, which stays off after an outage until you press it. It is a cheap fix for any setup, UPS or not.
Then restore the job. Home the machine. Bring back the work zero: one Onefinity owner photographs the offsets before each job and re-enters them with G92 in the MDI tab, rather than probing again. Re-zeroing after a power cut changed the Z depth of another owner's 3D relief. On Carbide Motion, use Program Restart from the line you noted. With no line, a 2021 Onefinity reply suggested running the job from the start, so the bit air-cuts the finished part until it reaches new work.
What this answer does not cover
The sizing uses published nameplate figures, not a meter on your machine. The Compact Router figure is a 2018 staff post, not a current spec sheet. Measure your own setup with a plug-in meter; measuring power draw shows how. The runtime figures assume new lead-acid batteries at room temperature, and an older UPS gives less. Program Restart was a beta feature when it was announced, so check that your Carbide Motion version has it. Nothing here makes a lift-out safe if you have to reach near a spinning bit to do it. Use the controller's pause and its Z move, and switch the router off before your hands go near it. For a cutter that must finish the job on battery, compare the laser cutter page. For a machine with its own power-loss recovery, see UPS for a 3D printer.
Frequently asked questions
Can a CNC router resume after a power outage?
Not on its own. Onefinity owners report the controller "will essentially reset itself back to first boot" and asks to home. Carbide Motion's Program Restart can start a job from a line you choose, but Carbide 3D says it does not yet track the last line executed through a power loss. You have to know the line, and your work zero, to restart.
Do I need a UPS for my CNC if outages are rare?
It depends on what a lost job costs you. Without one, an outage stops the job, resets the controller and leaves the bit in the cut. A UPS turns those blinks into nothing. If your power rarely blinks and your material is cheap, a lost job now and then may cost less than a 2200 VA pure sine unit.
Why not put only the controller on the UPS?
Because the machine keeps moving while the router spins down. Owners on both the Carbide 3D and Onefinity forums give the same warning: the gantry drags a stopped bit through the work, which ruins the part. If the router cannot go on battery, the controller should not either.
Does a CNC router need a pure sine wave UPS?
Use one. The router motor, a VFD's input stage and many PC power supplies are the loads a stepped wave suits worst, and the price gap is small next to a ruined board. Pure sine models such as APC's SMT series also come in the 2200 and 3000 VA sizes a router setup needs.
What should not go on the UPS in a CNC shop?
The dust collector or shop vac. Onefinity puts a typical shop vac at about 8 A, more than the router, and it can wait for the power to come back. Keep it on the wall. A spindle chiller is the exception: Carbide lists its CW3000 at 1 A at 110 V, and a water-cooled spindle should not run without it.
Sources and further reading
- Carbide 3D: 65mm VFD Spindle Kit, 110V and 65mm ER-16 spindle docs (110 V, 12 A, 1,200 W); 80mm VFD Spindle 220V and 80mm spindle kit docs (220 V, 12 A, L6-20, CW3000 at 1 A); Carbide Compact Router; Prepare for your machine
- Carbide 3D Community: Electrical usage for 1 hour's use (2018, William Adams, Carbide 3D); Carbide Motion 644 beta, now with Program Restart (March 2025); Uninterruptable power supply (UPS) (2018)
- Makita RT0701C product page (6.5 A, soft start)
- Onefinity CNC forum: Official power requirements for Onefinity (X-35/X-50) (2021, Onefinity CNC) and Power outages during operation (2021 to 2023)
- Avid CNC: Spindle / VFD system requirements
- LinuxCNC forum: Power outage and UPS; Schneider Electric (APC): SMT1500C, SMT2200C and SMT3000C product pages