On this page
An incubator is a thermostat, a heater, a fan and usually an egg turner in a plastic box, and the small ones draw about as much as a laptop. That makes it an easy UPS load. The harder question is what the UPS is protecting against, because a developing egg is more robust to a short chill than most people assume, and far less robust to too much heat.
This page puts the makers' wattage figures side by side, gives runtime per UPS size, and sets out what the makers and Penn State Extension say to do once the battery runs out.
What incubators draw, from the makers
Brinsea publishes two figures for each model, a typical draw and a maximum. The heater cycles on and off to hold temperature, so the typical figure is what to plan around and the maximum is the ceiling. Nurture Right gives one number.
| Model | Hen eggs | Typical | Maximum | Source |
|---|---|---|---|---|
| Brinsea Mini II (Eco, Advance, EX) | 7 to 10 | 12 W | 20 W | Brinsea comparison chart |
| Brinsea Maxi 24 EX | 24 | 24 W | 40 W | Product page and chart |
| Brinsea Ovation 28 EX | 28 | 30 W | 60 W | Product page and chart |
| Nurture Right 360 | 22 | Not stated | 60 W | Nurture Right FAQ |
| Brinsea Ovation 56 EX | 56 | 60 W | 115 W | Product page and chart |
The Nurture Right figure needs reading with care. Its FAQ answers "How many watts is the incubator?" with "60 watts," and lists its AC/DC adapter as "OUTPUT: 12V 5A," which is exactly 60 W. That looks like the supply's rating rather than a measured running draw. Treat 60 W as the ceiling, and expect the steady draw to sit well below it, as it does on every Brinsea model with a published typical figure.
The current ratings on the labels are not draw either. Brinsea lists the Maxi 24 EX supply as "100 - 240v, 50/60Hz, 1.3A max." At 120 V, 1.3 A would be 156 VA, four times the 40 W maximum. Size from the watts (VA vs watts explains why), and if you want your own number, put a plug-in meter on the incubator for a full day: how to measure power draw covers the method.
Runtime by UPS size
These estimates use the model behind our UPS runtime calculator: new sealed lead-acid batteries, a Peukert exponent of 1.25 referenced to the 20-hour rating, 88% inverter efficiency and 8 W of inverter overhead. Battery sizes are typical for each class. Why UPS runtime is not linear explains each term.
| UPS class (battery) | Mini II, 12 W | Maxi 24, 24 W | Ovation 28, 30 W | Maxi 24 max, 40 W | Ovation 56 or NR 360 max, 60 W |
|---|---|---|---|---|---|
| 600 VA (1 x 12 V 7 Ah, 84 Wh) | 2 h 25 min | 81 min | 65 min | 49 min | 31 min |
| 850 VA (1 x 12 V 9 Ah, 108 Wh) | 3 h 19 min | 1 h 51 min | 89 min | 67 min | 43 min |
| 1000 VA (2 x 12 V 7 Ah, 168 Wh) | 5 h 46 min | 3 h 12 min | 2 h 35 min | 1 h 56 min | 75 min |
| 1500 VA (2 x 12 V 9 Ah, 216 Wh) | 7 h 53 min | 4 h 23 min | 3 h 32 min | 2 h 38 min | 1 h 43 min |
| 2200 VA (2 x 12 V 18 Ah, 432 Wh) | 18 h 46 min | 10 h 26 min | 8 h 25 min | 6 h 17 min | 4 h 4 min |
The Ovation 56 at its 115 W maximum is not in the table: it would get about 15 minutes from a 600 VA unit and about 49 minutes from a 1500 VA tower. That is the warm-up draw, though, and a unit that is already at temperature will not sit there.
Here is the arithmetic for a Maxi 24 at its typical 24 W on a 1000 VA unit with two 12 V 7 Ah batteries:
A naive 168 Wh / 24 W says seven hours. The inverter's own consumption and the battery's lower capacity at higher current take more than half of that away.
Typical is not guaranteed on battery
A heater that holds 99.5°F has more work to do in a colder room. The same outage that takes the incubator onto battery often turns off the house heating, and a cooler room pushes the heater toward its maximum. In a winter outage, plan on a figure between typical and maximum, and treat the table's left-hand column for your model as the best case.
The rule the UPS is really serving: cooling is survivable, heat is not
The usual assumption is that the danger in an outage is cold. The makers and extension services say otherwise. Brinsea's power cut guidance is blunt: "Overheating is more of a danger than cooling, especially during the first week of incubation when the embryo is most delicate." It even notes that a cooling period of "30 to 40 minutes every 24 hours" is not harmful and may benefit development, and several of its models cool the eggs on purpose (the comparison chart lists "Periodic Cooling" on the Eco and EX lines).
Penn State Extension's classroom guide agrees: "Cooling off for a half-hour or so is nothing to be concerned about." Its instruction for a power failure is short: "reheat the incubator and continue as before." Nurture Right puts a number on it for its own unit: "Power outages of less than 10 minutes typically do not lead to a decrease in hatch rate."
Brinsea's temperature zones (for chicken eggs) show why the asymmetry exists:
| Zone | Range | What happens |
|---|---|---|
| Heat injury | Above 104.9°F (40.5°C) | Continued exposure kills embryos |
| Hatching potential | 84.5 to 104.9°F (29.2 to 40.5°C) | Development; 99.5°F (37.5°C) is the target |
| Disproportionate development | 80.6 to 95°F (27 to 35°C) | Uneven development and deformities |
| Suspended development | 28.4 to 80.6°F (-2 to 27°C) | Development stops; the range used for storing eggs before setting |
| Cold injury | Below 28.4°F (-2°C) | Ice crystal damage |
The target of 99.5°F sits less than 6°F below the heat injury line and more than 18°F above the point where development stops. An egg cooling through the middle zone for hours is the slow problem; an egg pushed a few degrees too hot is the fast one.
Our analysis: what a UPS actually buys you
Not survival through a ten-minute flicker, which the makers say the eggs tolerate anyway. What it buys is time without a decision. Brinsea's cool-down rule turns on a two-hour mark, and outages often happen at night or while you are out. A UPS that holds the incubator at temperature for two to four hours means the clock on that decision does not start until the battery is gone. On a Maxi 24, that is a 1000 VA unit or larger; on a Mini II, a 600 VA unit already gets you there.
When the battery runs out: the cool-down rule
Brinsea splits its advice at day 14 of a 21-day chicken incubation.
- Days 1 to 14, outage under two hours: Brinsea's chilling advice does not apply. Penn State's instruction does: when power returns, "reheat the incubator and continue as before."
- Days 1 to 14, outage past two hours: Brinsea says "it is actually better to chill the eggs to a range of 41° - 68°F" (5 to 20°C) because "this suspends development safely." It notes losses rise the further development has progressed.
- After day 14: do the opposite. The embryos' own metabolic heat gives some warmth for a while, and Brinsea says to "keep the lid on the incubator and, if possible, raise the temperature in the room."
That last step is where people get into trouble. Warm the room with whatever heating you would normally use; do not put a heat source on or next to the incubator, and do not plug a space heater into a UPS. A space heater would drain a home UPS in minutes and can overload its inverter. A blanket over the unit is no better: Nurture Right does not recommend covering its incubator even in a cold room, because the eggs need air to release carbon dioxide.
Setting it up
- Battery outlet, not surge-only. Most UPS units have both. The incubator goes on a battery-backed outlet; a candling lamp or brooder heat lamp does not. Once the chicks hatch, a heat plate for the brooder runs for hours on a UPS, where a 250 W lamp gets minutes.
- Keep the UPS audible. The incubator's own alarms only fire when its temperature drifts, and on a UPS that will not happen until the battery is nearly flat. The UPS's on-battery beep is your outage alert; see UPS beeping for what each pattern means.
- Do a timed test before you set eggs. Run the empty incubator at temperature, unplug the UPS from the wall and note how long it lasts. That is your real number, including your room temperature and battery age.
- Check the controller after any outage. Nurture Right says its 360 keeps settings in "a built-in memory chip," but suggests correcting the days-to-hatch timer after a long one. Other makers do it differently; your manual is the authority.
- Waveform. No maker page cited here asks for pure sine. If you are buying new anyway, pure sine removes the doubt.
Where this answer stops applying
- Long outages. Even a 2200 VA tower runs a Maxi 24 for about ten hours. For a storm that lasts days, a portable power station or generator is the right tool, and how much runtime do you need helps you decide between them.
- 12 V incubators. The Nurture Right runs from a 12 V adapter, so a DC battery could in principle skip the inverter loss entirely; DC mini UPS vs AC UPS explains the trade. Nurture Right warns that aftermarket power cords are "not covered by the product's 1 year limited warranty," so ask the maker before you try it.
- Cabinet incubators and other species. The figures here are for tabletop units and the zones are Brinsea's for chicken eggs. Larger cabinets draw more, and other species run on different schedules.
An incubator has a lot in common with a fish tank on battery: a few tens of watts that need to run for hours, not minutes. The aquarium guide works through the same problem with oxygen in place of heat.
Frequently asked questions
How many watts does an egg incubator use?
Tabletop forced-air models in the 7 to 56 hen egg range are rated at 12 to 60 W typical. Brinsea lists the Mini II at 12 W, the Maxi 24 at 24 W, the Ovation 28 at 30 W and the Ovation 56 at 60 W, each with a maximum roughly double that. The Nurture Right 360 FAQ says 60 W, the same as its 12 V 5 A adapter's output.
How long can incubating eggs go without power?
Penn State Extension says "cooling off for a half-hour or so is nothing to be concerned about," and Nurture Right says outages under 10 minutes typically do not lower hatch rates. Brinsea draws its line at two hours: past that in the first 14 days, it advises chilling the eggs to 41 to 68°F to suspend development instead of letting them sit partly warm.
Will my incubator lose its settings in a power cut?
The Nurture Right 360 FAQ says it has "a built-in memory chip to remember all of the settings data," though after a long outage you may want to correct the days-to-hatch timer. Other makers handle this differently, so check your manual. A UPS avoids the question entirely, because the controller never sees the outage.
Can I wrap the incubator in a blanket during an outage?
Brinsea's late-stage advice is to keep the lid on and raise the room temperature, not to seal the unit. Nurture Right does not recommend covering its incubator with a towel even in a cold room, because the eggs need air exchange to release carbon dioxide. Warm the room instead.
Is a simulated sine UPS OK for an incubator?
None of the maker pages cited here states a waveform requirement. The Brinsea models listed run on 100 to 240 V or switchable mains supplies, and the Nurture Right uses a 12 V adapter; electronics like these generally run fine on either waveform. A pure sine unit removes the doubt if you are buying new.
Sources and further reading
- Brinsea: Power cuts and their effect on incubating eggs
- Brinsea: Maxi 24 EX fully automatic egg incubator, specifications
- Brinsea: Ovation 28 EX fully automatic egg incubator, specifications
- Brinsea: Ovation 56 EX fully automatic egg incubator, specifications
- Brinsea: Incubator comparison chart (power consumption, egg capacity)
- Manna Pro / Harris Farms: Nurture Right 360 incubator frequently asked questions
- Penn State Extension: Embryology, maintaining the incubator