How to Keep a Chick Brooder Warm in a Power Outage

It depends on the heater. Heat plates from Brinsea and Premier 1 draw 12 to 66 W, so a common 1500 VA UPS keeps a 12 W Brinsea EcoGlow Safety 600 warm for about 8 hours. A 250 W heat lamp drains the same UPS in about 19 minutes. So a UPS is a real answer for a heat plate and a poor one for a lamp.

On this page
  1. What brooder heaters draw
  2. Runtime by heater and UPS size
  3. Worked case: 20 day-old chicks on a 1500 VA UPS
  4. Setting it up
  5. Can I run a 12 V EcoGlow straight from a battery?
  6. When the battery runs out
  7. Where this answer stops applying
  8. Frequently asked questions

The answer comes down to one number: the heater's watts. Chick heaters come in two kinds, and they sit about twenty times apart. A UPS can carry one kind for hours. It carries the other for minutes.

First, the terms. A brooder is the warm pen where chicks live for their first weeks, before they can hold their own body heat. A heat lamp is a bulb, usually a 250 W red infrared one, hung over the pen to warm the floor below it. A heat plate (also sold as a brooder plate or heating plate) is a flat heated panel on short legs. The chicks crouch under it and warm themselves by touch, the way they would under a hen. A UPS (uninterruptible power supply) is a battery box that keeps its outlets live when the wall power fails. Its runtime is how long it lasts before the battery is flat.

What brooder heaters draw

Brinsea and Premier 1 publish one watt figure per plate. Brinsea's plates run at 12 V. Its product pages describe "Safe 12 volt operation from a mains transformer supplied," so the plate plugs into the wall through a power brick. Premier 1's plates plug straight into the outlet.

Rated watts for chick brooder heaters, from the makers and Manitoba Agriculture
HeaterWattsChicks (maker's figure)Source
Brinsea EcoGlow Safety 60012 WUp to 20 newly hatchedBrinsea product page
Premier 1 heating plate, extra small (10 x 10 in)15 WUp to 15Premier 1 specs
Brinsea EcoGlow Safety 120018 WUp to 35 newly hatchedBrinsea product page
Premier 1 heating plate, small (12 x 12 in)22 WUp to 20Premier 1 specs
Premier 1 heating plate, medium (16 x 16 in)42 WUp to 30Premier 1 specs
Premier 1 heating plate, large (16 x 24 in)66 WUp to 50Premier 1 specs
Red or clear heat lamp250 WUp to 100 per single lampManitoba Agriculture

Premier 1 puts the gap in plain words: "Only 15 watts (66 for the larger plate) vs 175 or 250 watts for a heat lamp." Manitoba Agriculture says a brooder lamp takes "a 250-watt red or clear bulb," hung 18 to 24 inches off the floor.

One detail matters more on battery than at the wall. Neither plate has a thermostat. The chicks set their own comfort by moving in and out from under it. Brinsea's EcoGlow manual says they "will find their own comfortable temperature" that way. Premier 1 says that plugged straight in, its plate's red light "comes on and stays on." So the plate draws its full rating all the time. Unlike an incubator, there is no typical figure below the maximum to plan around. A heat lamp may or may not have one. Manitoba notes that some have thermostatic controls, while others are raised or lowered to set the heat.

The one exception is Premier 1's optional controller. Premier 1 says it sets the plate's output "between 20% - 100% of full output." A plate on that controller turned down draws less than its rating.

Runtime by heater and UPS size

These estimates use the model behind our UPS runtime calculator. It assumes new sealed lead-acid batteries, 88% inverter efficiency and 8 W used by the UPS itself. It also allows for lead-acid batteries giving more of their capacity at low current. Battery sizes are typical for each class. UPS runtime explained covers each term.

Estimated runtime by brooder heater and UPS class (new batteries, heater at full rated watts)
Heater600 VA (1 x 12 V 7 Ah)1000 VA (2 x 12 V 7 Ah)1500 VA (2 x 12 V 9 Ah)2200 VA (2 x 12 V 18 Ah)
EcoGlow Safety 600, 12 W2 h 25 min5 h 46 min7 h 53 min18.8 h
Premier 1 extra small, 15 W2 h 2 min4 h 50 min6 h 38 min15.8 h
EcoGlow Safety 1200, 18 W1 h 45 min4 h 9 min5 h 41 min13.5 h
Premier 1 small, 22 W88 min3 h 28 min4 h 45 min11.3 h
Premier 1 medium, 42 W46 min1 h 50 min2 h 31 min6.0 h
Premier 1 large, 66 W28 min67 min1 h 32 min3 h 39 min
Heat lamp, 175 W9 min22 min30 min71 min
Heat lamp, 250 W6 min14 min19 min46 min

A 250 W lamp is well inside what each of these classes can supply. Even a 600 VA unit is usually rated around 360 W (VA vs watts explains the two ratings). So the lamp does not overload the UPS. It just empties it.

Worked case: 20 day-old chicks on a 1500 VA UPS

Take a brood of 20 chicks in their first week. Three heaters are rated for a pen that size: a Brinsea EcoGlow Safety 600, a Premier 1 small plate, or one 250 W lamp. Suppose the heater is on the battery side of a 1500 VA UPS with two 12 V 9 Ah batteries. The power fails at 10 pm.

Here is the arithmetic for the Safety 600. The UPS's own 8 W is added to the load, then the inverter's losses:

Battery draw = (12 W + 8 W) / 0.88 = 22.7 W, or 0.95 A at 24 V
Runtime = 20 h x (9 Ah / (0.95 A x 20 h))^1.25 = about 7.9 hours

Worked the same way for each heater, that gives:

  • EcoGlow Safety 600, 12 W: about 7 h 53 min. The plate stays warm until about 6 am.
  • Premier 1 small plate, 22 W: about 4 h 45 min. The plate goes cold a little before 3 am.
  • 250 W heat lamp: about 19 minutes. The lamp goes out at about 10:19 pm.

The lamp draws about 21 times the watts of the Brinsea plate, but its runtime is about 25 times shorter. That is because lead-acid batteries give up less of their capacity when drained fast. A naive 216 Wh / 250 W says 52 minutes. The real figure is well under half that.

Our analysis: the UPS decides nothing, the heater does

The usual advice splits two ways. One camp says a UPS cannot run a brooder. For a lamp that is right, and the lamp is the common setup: My Pet Chicken calls lamps "the most popular heating device for baby chicks." The other camp says a heat plate runs all night on a UPS. That is only true for a small plate on a 1500 VA unit or larger. A 600 VA unit gives the Safety 600 under two and a half hours. A large Premier 1 plate gets about an hour and a half even from a 1500 VA tower. So read your own row. If you are buying a heater with outages in mind, the smallest plate that fits your brood is the one that buys the most hours.

Setting it up

  • Plate on a battery outlet, lamp off it. Most UPS units have two banks of outlets. One is battery-backed and one is surge-only, which goes dead in an outage (UPS outlets and plugs explains the split). If you run a lamp beside a plate, put the lamp on the surge-only bank. The UPS then sheds it by itself.
  • Watch the 15 W line. APC says Back-UPS models with No-load Shutdown "shut down while operating on battery power when the attached load is less than 15 watts." It happens after about 15 minutes. The 12 W Safety 600 is under that line, and so can be a Premier 1 plate turned down on its controller. APC's FAQ shows how to switch the feature off in Program Mode. Not every model has it, so check your manual. Then test: unplug the UPS from the wall with only the brooder on it and wait 20 minutes. If it goes dark, see UPS shuts off during an outage.
  • Time your own setup. Do the same unplug test for longer before the chicks arrive. Your battery's age and your room change the number. A plug-in meter shows your heater's true draw; how to measure power draw covers the method.
  • Keep the UPS where you can hear it. A plate has no alarm. The UPS beep is your only sign that the power is out.

Can I run a 12 V EcoGlow straight from a battery?

It is a natural question. The plate runs at 12 V, and a car battery is 12 V. But Brinsea does not document it. Its pages describe 12 V operation "from a mains transformer supplied." The US manual for the earlier EcoGlow goes further: "To provide continued electrical safety only use the power supply unit supplied for the EcoGlow chick brooder by Brinsea Products Inc." Nothing Brinsea publishes covers a battery, a car socket or a different 12 V supply. So this page does not recommend it. If you want more hours than a UPS gives, run the plate on its own transformer from a bigger battery source, such as a portable power station. Premier 1's plates plug straight into a wall outlet, so they have no 12 V option to ask about.

When the battery runs out

Chicks can move toward heat or away from it, and that gives you options. My Pet Chicken lists the ones that need no power at all:

  1. Hot water bottles. A customer of theirs lost power for about 15 hours in Hurricane Irene. She heated water on a grill, put the bottles in old tube socks "to keep the chicks from being scalded," and got up at 2:30 am to reheat them. The chicks "made it to morning."
  2. Canning jars. Fill them with hot water, use sealed lids so nothing spills, and wrap each jar in a towel.
  3. Bricks or rocks. Warm them in an oven or on a grill, lift them with oven mitts and wrap them in a towel.
  4. Warming packs. Disposable packs made for reptile enclosures or animal shipping can work for a while.
  5. Insulate. A towel over part of the top stops drafts. Extra bedding warms the floor, and a blanket can wrap the sides.

Unplug the heater before you cover the brooder

My Pet Chicken's rule: "be sure to UNPLUG your heat lamp or other heat source first, or it could start a fire or overheat your chicks when the power comes back on." Then watch for the power to return, take the cover off, and turn the heater back on. My Pet Chicken also says a lamp's surface can "exceed 400 degrees." Brinsea's EcoGlow manual says not to cover the brooder panel in any way, because it "may cause it to overheat."

Watch the chicks, not just a thermometer. Manitoba Agriculture says cold birds "will huddle and pile," while birds that are too hot "crowd as far from the lamps as possible." Its target is 90 to 95°F (32 to 35°C) on the floor at the edge of the heat in the first week, then 5°F (3°C) less each week until room temperature, 70°F (20°C), is reached. So the first weeks, when the target is highest, are the risky ones. By six weeks, Manitoba's range is 65 to 70°F (18 to 21°C).

The same problem with eggs is harder. Chicks can find the warm spot, but eggs cannot move. The egg incubator guide covers what to do when the incubator loses power, and why cooling there is safer than too much heat. The reptile heat mat guide reaches the same verdict as this page: the low-watt heater goes on battery, and the lamp comes off.

Where this answer stops applying

The runtimes are model estimates for new batteries at each heater's full rated watts. An older battery gives less, and only a timed test of your own setup gives the true number. A warm plate is also not the same as a warm chick. Brinsea says its brooders are for indoor use and the room "should not drop below 50°F (10°C)." A winter outage that shuts off the house heat can take a garage or shed below that, and then a plate on a UPS may not be enough. Neither Brinsea nor Premier 1 says whether its power brick or controller works on a UPS with a stepped, "simulated" sine wave. A pure sine unit removes the doubt; otherwise, check that the plate warms during your unplug test. This page covers power, not chick care. Ducklings, poults and other birds have their own heat needs, so follow your hatchery or extension service on those. For an outage that lasts days, a UPS is the wrong tool, and a power station or generator is the right one.

Frequently asked questions

How long will a UPS run a chick heat plate?

A 12 W Brinsea EcoGlow Safety 600 gets about 2 h 25 min from a 600 VA UPS, 7 h 53 min from a 1500 VA unit and 18 h 46 min from a 2200 VA tower. A 22 W Premier 1 small plate gets about 88 minutes, 4 h 45 min and 11.3 hours. These are estimates for new batteries.

Can I run a heat lamp on a UPS?

Only for minutes. A 250 W lamp gets about 6 minutes from a 600 VA UPS, 19 minutes from a 1500 VA unit and 46 minutes from a 2200 VA tower. That is enough to bridge a flicker, not a night. Put the lamp on a surge-only outlet and use a heat plate on the battery side.

Can I run a Brinsea EcoGlow from a 12 V car battery?

Brinsea does not say you can. Its product pages describe 12 V operation "from a mains transformer supplied," and its US manual for the earlier EcoGlow says to use only the power supply unit Brinsea supplies. With no maker guidance, this page does not recommend it. Power the transformer from a UPS or a power station instead.

Why does my UPS turn off after 15 minutes with only the brooder plugged in?

It may have a light-load cutoff. APC says Back-UPS models with No-load Shutdown turn off on battery when the load is less than 15 watts, after about 15 minutes. A 12 W EcoGlow Safety 600 is under that line. APC's FAQ shows how to switch it off in Program Mode.

Can I put a blanket over the brooder to hold heat in a power outage?

My Pet Chicken suggests a towel over the top and blankets around the sides, but says to unplug the heat lamp or other heat source first. Otherwise it could start a fire or overheat the chicks when the power comes back. Brinsea's EcoGlow manual says not to cover the brooder panel in any way.

Sources and further reading

  1. Brinsea: EcoGlow Safety 600 chick brooder, specifications
  2. Brinsea: EcoGlow Safety 1200 chick brooder, specifications (listed with the 600 at Brinsea chick brooders)
  3. Brinsea: EcoGlow chick brooder user instructions, US (HD500)
  4. Premier 1 Supplies: Heating plates and covers, specs (read from the September 2025 archived copy)
  5. Manitoba Agriculture: Brooding temperatures for small poultry flocks
  6. My Pet Chicken: How can I keep my brooder warm during a power outage?
  7. My Pet Chicken: Infrared heat lamp bulb, red, 250 watts
  8. APC by Schneider Electric FAQ000210003: Back-UPS No-load Shutdown