How Long Will a UPS Run a Reptile Heat Lamp or Heat Mat?

It depends almost entirely on the heater's watts. A common 1500 VA UPS runs an 8 W Zoo Med ReptiTherm heat mat for about 10 hours, but a 100 W ceramic heat emitter for under an hour. So in an outage the heat mat goes on the battery outlet, and the emitter and basking lamp come off it.

On this page
  1. What Zoo Med's heaters draw
  2. Runtime for each heater
  3. Worked case: a 40-gallon tank with a mat and an emitter
  4. Two forum answers that are both half right
  5. Thermostats: two traps
  6. When the battery runs out
  7. Where this answer stops applying
  8. Frequently asked questions

The answer is a single number: the heater's watts. A heat mat uses a few watts and a heat lamp uses dozens or more. The same UPS that keeps a mat warm all night runs a ceramic emitter for less than an hour. So the real question is not whether a UPS works for reptiles. It is which heater you put on it.

First, the terms. A UPS (uninterruptible power supply) is a battery box that keeps its outlets live when the wall power fails. Its runtime is how long it does that before the battery is flat. A heat mat, or under tank heater, is a thin pad stuck under the glass that warms the floor. A ceramic heat emitter (CHE) screws into a lamp socket like a bulb but gives heat and no light. A basking bulb is a spot lamp that gives both heat and light.

What Zoo Med's heaters draw

Zoo Med publishes one watt figure for each heater. That figure is the most it can draw. On a thermostat it draws less on average, but in a cold room during an outage the thermostat keeps it on most of the time. Plan on the full number.

Rated watts for Zoo Med reptile heaters, from Zoo Med's product pages
HeaterItemWattsZoo Med's tank size
ReptiTherm heat mat, MiniRH-74 W1 to 5 gallons
ReptiTherm heat mat, SmallRH-48 W10 to 20 gallons
ReptiTherm heat mat, MediumRH-516 W30 to 40 gallons
ReptiTherm heat mat, LargeRH-624 WNot stated
ReptiCare ceramic heat emitterCE-6060 W
ReptiCare ceramic heat emitterCE-100100 W
ReptiCare ceramic heat emitterCE-150150 W
Repti Basking Spot lampSL-25 to SL-25025 to 250 W

The basking lamp comes in 25, 40, 50, 75, 100, 125, 150 and 250 W. The smallest heat mat and the largest basking lamp are more than 60 times apart. That gap is the whole story of this page.

The watts on a box are the maker's rating. To know what your own setup uses over a night, put a plug-in meter on it. How to measure power draw shows the method.

Runtime for each heater

These estimates use the model behind our UPS runtime calculator. It assumes new sealed lead-acid batteries, 88% inverter efficiency and 8 W used by the UPS itself. It also allows for lead-acid batteries giving more of their capacity at low current. Battery sizes are typical for each class. UPS runtime explained covers each term.

Estimated runtime by heater and UPS class (new batteries, heater at full rated watts)
Heater600 VA (1 x 12 V 7 Ah)1000 VA (2 x 12 V 7 Ah)1500 VA (2 x 12 V 9 Ah)2200 VA (2 x 12 V 18 Ah)
Mini mat, 4 W4 h 35 min10.9 h14.9 h35.5 h
Small mat, 8 W3 h 12 min7 h 37 min10.4 h24.8 h
Medium mat, 16 W1 h 56 min4 h 35 min6 h 17 min14.9 h
Large mat, 24 W81 min3 h 12 min4 h 23 min10.4 h
CE-60 emitter, 60 W31 min75 min1 h 43 min4 h 4 min
75 W basking lamp25 min58 min80 min3 h 10 min
CE-100 emitter, 100 W18 min42 min58 min2 h 17 min
CE-150 emitter, 150 W11 min26 min36 min85 min

Here is the 1500 VA row for the 8 W Small mat. The UPS's own 8 W is added to the load, then the inverter's losses:

Battery draw = (8 W + 8 W) / 0.88 = 18.2 W, or 0.76 A at 24 V
Runtime = 20 h x (9 Ah / (0.76 A x 20 h))^1.25 = about 10.4 hours

Read down the 1500 VA column. The 8 W mat runs about 10 hours. The 100 W emitter runs 58 minutes, under a tenth of that. The emitter draws 12.5 times as much, and lead-acid batteries give up less of their capacity when drained fast.

Worked case: a 40-gallon tank with a mat and an emitter

Take a 40-gallon tank. It has a Medium ReptiTherm mat (16 W), which Zoo Med sizes for 30 to 40 gallons. It also has a CE-100 emitter (100 W) overhead for air heat. Suppose both are plugged into the battery side of a 1500 VA UPS with two 12 V 9 Ah batteries. The power fails on a winter night.

  • Both on battery: 116 W. The calculator model gives about 48 minutes. Then both go cold together.
  • Emitter moved to a surge-only outlet: 16 W. The same battery now runs the mat for about 6 hours 17 minutes.

Unplugging one heater buys almost eight times the warm time. The animal keeps a warm floor to sit on for most of a night, not most of an hour. The emitter was the larger heater. It was also the one the battery could not carry.

Our analysis: the mat goes on battery, the lamp comes off

Most UPS units have two banks of outlets. One bank is battery-backed. The other is surge-only, and it goes dead in an outage (see UPS outlets and plugs). Put the heat mat and its thermostat on the battery bank. Put the emitter and the basking lamp on the surge-only bank. That way the setup sheds the big loads by itself, even if the outage starts while you sleep.

Two forum answers that are both half right

Keepers have argued this for years, and the two camps are each looking at a different heater.

First, the "not long enough" camp. In a 2011 ball-pythons.net thread, kitedemon granted that some UPS units have pure output. The same post adds that "generally they will not power any heating system for long enough to be useful." It planned 2 or 3 deep cycle marine batteries for about 12 hours. In a 2021 MorphMarket thread, a member who runs a 250 lb lab UPS said they see "20-30 minutes worth of power" from it. That was on mass spectrometers, not a heat mat.

Then the "one to four hours" camp. Furry Critter Network says a computer UPS "can keep thermostats and ceramic heat emitters running during short outages of one to four hours."

The table settles it. For an emitter, both are close. A CE-60 or CE-100 gets roughly 1 to 4 hours from a 1500 or 2200 VA unit, and under 35 minutes from a 600 VA one. That is not a night. For a mat, the "not long enough" view is wrong. An 8 W mat gets about 10 hours from a 1500 VA unit and about 25 from a 2200 VA tower. The doubt persists because most keepers picture the lamp, and the lamp is the part a UPS cannot hold.

Thermostats: two traps

A tiny mat can fall under the light-load cutoff

Some UPS units switch themselves off on battery when the load is very small. APC says Back-UPS models with No-load Shutdown "shut down while operating on battery power when the attached load is less than 15 watts." It happens after 15 minutes. A 4 W Mini or an 8 W Small mat is under that line. So is a 16 W mat when its thermostat has it switched off.

The fix is in APC's FAQ. With the UPS off and plugged into the wall, hold the power button until the light flashes. That is Program Mode, where you can switch the feature off. Not every model has it, and other brands handle light loads their own way. Check your manual, then test it: unplug the UPS from the wall with only the mat on it and wait 20 minutes. If the UPS goes dark, see UPS shuts off during an outage.

Dimming thermostats need a pure sine UPS

Reptile thermostats work in one of two ways. An on/off thermostat clicks the heater fully on, then fully off. A proportional thermostat feeds the heater only part of the power. The Herpstat 6 manual describes both forms. Its Heat (Dimming) mode adjusts "the voltage output to the heating device similar to a household dimmer." Its Heat (Pulse) mode gives "varied lengths of pulsed power."

That kind of control needs a smooth wave. Many lower-cost UPS units make a stepped, "simulated" sine wave instead (pure sine vs simulated sine explains the difference). In the 2011 ball-pythons.net thread, a member posted a reply from Jeff Washburn of Helix Controls. It said a UPS wave is "square-ish" and "not acceptable for use with triac driven devices," including "any truely Proportional thermostat." The failure the reply names is the worrying one: it "tends to turn on the power at a low level when the system wants the power OFF." On/off thermostats, the reply said, "(at least most of them) should not have this problem."

So the rule is short. A dimming or pulse thermostat goes on a pure sine UPS. An on/off thermostat can use either kind.

When the battery runs out

A UPS buys hours, not days. In the MorphMarket thread, the member who started it had to warm a ball python under their shirt. Keepers there and on ball-pythons.net list the next steps:

  1. Keep heat in. Blankets or foam panels over the enclosure slow the drop. Furry Critter Network calls insulation "your best friend during extended outages."
  2. Add chemical heat. One ball-pythons.net member's plan was "Short term: Hot Water Bottles, UPS. Longer term: 40 or 60 hour heat packs." A MorphMarket member bought packs said to last "~40 hours."
  3. Wrap it. Furry Critter Network says a hand warmer's surface "can exceed 150 degrees Fahrenheit." Wrap it in cloth, and keep it off the animal and off bare glass.
  4. Go bigger for long outages. A portable power station or a generator is the tool for a day or more.

An egg incubator is a close cousin of this problem: a few tens of watts of heat that must run for hours. The aquarium guide reaches the opposite verdict on heaters, because there oxygen matters first.

Where this answer stops applying

The runtimes are model estimates for new batteries at each heater's full rated watts. An older battery gives less, and a mat on a thermostat in a warm room uses less. The only true number is a timed test of your own setup. This page covers power, not animal care. How cold your species can safely get, and for how long, is a question for its care sheet or a reptile vet. A heater on a UPS can still fail the animal if the thermostat misbehaves, so a probe thermometer in the enclosure is still the thing to watch. The pure sine rule comes from one thermostat maker's reply and one manual. If your thermostat's maker says something different about UPS power, follow the maker. Finally, never run a space heater on a UPS to warm the reptile room. A 1,500 W heater is more than a 1500 VA desktop UPS can supply at all, since those units are rated well under 1,500 W.

Frequently asked questions

How long will a UPS run a heat mat?

On a 1500 VA UPS with two 12 V 9 Ah batteries, about 15 hours for a 4 W Zoo Med Mini, 10 hours for an 8 W Small, 6 hours for a 16 W Medium and 4 hours for a 24 W Large. A small 600 VA unit gives roughly a third of that. These are estimates for new batteries at the mat's full rated watts.

Can a UPS run a ceramic heat emitter overnight?

Not a desktop one. A 100 W emitter gets about 58 minutes from a 1500 VA UPS and about 2 hours 17 minutes from a 2200 VA tower with two 18 Ah batteries. For a whole night on an emitter you need a power station or a generator. A heat mat is the load a UPS can carry overnight.

Do I need a pure sine UPS for a reptile thermostat?

Only if the thermostat dims or pulses the power. Helix Controls told a ball-pythons.net member that a stepped UPS wave is "not acceptable for use with triac driven devices", which includes any truly proportional thermostat. An on/off thermostat, the kind that just clicks the heater on and off, "should not have this problem."

Why does my UPS turn off after 15 minutes with only a heat mat plugged in?

It may have a light-load cutoff. APC says Back-UPS models with No-load Shutdown shut down after 15 minutes on battery when the load is under 15 watts. A 4 W or 8 W mat is under that line. APC's FAQ shows how to switch the feature off in Program Mode, if your model has it.

What do I do when the UPS battery runs out?

Keep the heat in the enclosure. Forum keepers use 40 to 60 hour heat packs, hot water bottles and blankets over the tank. Furry Critter Network warns that a hand warmer can pass 150°F, so wrap it in cloth and keep it off the animal and off bare glass.

Sources and further reading

  1. Zoo Med: ReptiTherm Under Tank Heater, sizes and wattages
  2. Zoo Med: ReptiCare Ceramic Infrared Heat Emitter (CE-60, CE-100, CE-150)
  3. Zoo Med: Repti Basking Spot Lamp, item numbers SL-25 to SL-250
  4. APC by Schneider Electric FAQ000210003: Back-UPS shuts down after 15 minutes on battery (No-load Shutdown)
  5. Spyder Robotics: Herpstat 6 manual (Heat Dimming and Heat Pulse modes)
  6. ball-pythons.net: back up power questions (December 2011, includes the Helix Controls reply) and Heating during power outages? (July 2010)
  7. MorphMarket Community: Power outage (February 2021)
  8. Furry Critter Network: Backup Systems (reptile articles)