On this page
Yes, a UPS can run a plug-in electric fence charger, and for longer than most loads. Zareba says its 75-mile EAC75M-Z draws 14 W. A common 1500 VA UPS carries that for about 7 hours. That covers most outages. It does not cover a storm that takes the power for days. For that, a charger that runs from its own battery is the better tool.
First, the terms. An electric fence charger (also called an energizer or fencer) sends a short, high-voltage pulse down the fence wire about once a second. An animal that touches the wire feels the pulse as a sharp shock. A plug-in or AC charger runs from a wall outlet. A DC charger runs from a 12 V battery instead. Low impedance describes the charger's output. Zareba defines it this way: "there is less resistance (or impedance) in the charger so more power can be pushed through the wire." That helps the pulse stay strong when weeds touch the fence. A UPS (uninterruptible power supply) is a battery box that keeps its outlets live when the wall power fails.
How much power a fence charger draws
Fence chargers are rated in miles and joules, not watts. The joule figure is the energy in each pulse. The power the charger takes from the outlet is a separate number, and it is rarely on the box. Zareba has answered it for three of its chargers in the questions on its own product pages.
| Charger | Power | Output | Draw | What Zareba said |
|---|---|---|---|---|
| EAC75M-Z, 75 miles | 115 V AC plug-in | 4 J at 75 ohms | 14 W | "This unit draws 14 watts of power during operation." |
| EAC100M-Z, 100 miles | 115 V AC plug-in | 6 J at 75 ohms | under 1 A (ceiling, not a figure) | "All AC-powered chargers, including model EAC100M-Z, have an amp draw of less than one amp." |
| EDC25M-Z, 25 miles | 12 V battery | 1 J at 200 ohms | 0.113 A, 1.4 W | "approximately 33.6 Watt-hours per day" |
Read the EAC100M-Z answer with care. "Less than one amp" is a limit, not a measurement. At 115 V, one amp is 115 W. So the charger draws somewhere under 115 W, and Zareba does not say where. The same answer covers "all AC-powered chargers," so it tells you the most any Zareba plug-in model can draw. It does not tell you what yours actually draws.
That gap matters for runtime. A UPS lasts about 7 hours at 14 W but under an hour at 115 W. If your charger's maker gives no watts, measure them. A plug-in watt meter does it in a minute; how to measure power draw shows the method. Measure with the fence connected, since Zareba says "the more weeds touching your fence line, the more draw from your charger."
Worked through: a Zareba EAC75M-Z on a 1500 VA UPS
Take a garden fence run by a Zareba EAC75M-Z. Suppose it plugs into the battery side of a 1500 VA UPS with two 12 V 9 Ah batteries. Those two batteries hold 216 Wh. The power fails at 9 pm.
These figures use the model behind our UPS runtime calculator. It assumes new batteries, 88% inverter efficiency and 8 W used by the UPS itself. It also allows for lead-acid batteries giving more of their capacity at low current. UPS runtime explained covers each term.
Runtime = 20 h x (9 Ah / (1.04 A x 20 h))^1.25 = about 7 hours
So the fence stays hot until about 4 am. If the power is back by then, the animals never noticed.
Our analysis: the UPS uses more than half as much as the charger
At a load this small, the UPS's own running cost is a big share of the battery. In the sum above, 14 W goes to the charger and 8 W goes to the UPS. Then the inverter loses about 3 W more turning battery power into 120 V. So close to half of what leaves the battery never reaches the fence. That is why a 12 V DC charger on a battery of the same size lasts so much longer. It skips the inverter step entirely.
Runtime by UPS size
Here is the same math across the common UPS sizes. The 115 W row is the EAC100M-Z at its ceiling. Treat it as the worst case for any Zareba plug-in model, not as a typical figure.
| Charger draw | 600 VA (1 x 12 V 7 Ah) | 1000 VA (2 x 12 V 7 Ah) | 1500 VA (2 x 12 V 9 Ah) | 2200 VA (2 x 12 V 18 Ah) |
|---|---|---|---|---|
| 14 W (Zareba EAC75M-Z) | about 2 h 10 min | about 5 h 5 min | about 7 h | about 16 h 40 min |
| 115 W (ceiling for Zareba AC models) | about 15 min | about 35 min | about 50 min | about 1 h 55 min |
Neither load comes close to overloading any of these units. The question is never whether the UPS can power the charger. It is how long the battery lasts.
The 15 W trap
A small charger can switch some UPS units off. APC says its "Back-UPS products with No-load Shutdown functionality enabled will shut down while operating on battery power when the attached load is less than 15 watts." That happens after 15 minutes on battery. A 14 W charger is just under the line.
So the fence would go dead a quarter hour into the outage, with hours of battery left. APC's FAQ shows how to turn the feature off. Not every Back-UPS has it, so check your manual. Then test. With only the charger plugged in, switch off the breaker that feeds the UPS and wait 20 minutes. If the UPS goes dark, see why a UPS shuts off during an outage. The same trap catches other small loads, like a 12 W heat plate in a chick brooder. Plugging a second small load into the battery side can lift the total above 15 W, but it also shortens the runtime.
Does a fence charger care about simulated sine?
Many lower-cost UPS units make a simulated sine wave on battery. That is a stepped, blocky copy of the smooth wave from the wall. Pure sine vs simulated sine explains the difference and which loads mind it.
No source we could find settles this for fence chargers. Zareba's and Gallagher's pages say nothing about inverters or waveform. We also searched six energizer manuals from Gallagher, JVA, Premier 1 and Kencove. None mentions inverters or waveform. "Low impedance" does not answer it either. By Zareba's own definition, the term describes the charger's output into the fence, not what the charger needs from the outlet.
So the honest answer is that nobody publishes one. There are two ways to stop guessing. A pure sine UPS removes the question, since its battery output is the same shape as the wall's. On a simulated sine UPS, test it. Read the fence voltage with a fence tester on wall power. Then switch off the UPS's breaker and read it again on battery. If the reading holds and the charger keeps its steady pulse, it is working.
Three ways to keep the fence hot
A UPS is the cheapest route if you already own one. It is not the only one, and for long outages it is not the best.
A dedicated battery backup: Gallagher G58211
Gallagher sells a backup unit made for this job. Its Canadian store lists the G58211 as "compatible with MB and MBS i Series and the MBS range of Energizers." Gallagher says that in a mains failure, "the power source automatically switches your Gallagher MB/MBS Energizer to the external 12V battery." When the mains is on, "the battery is trickle charged." LEDs show whether the system is on mains or battery. The unit fits "between the mains power supply and the Energizer." The list price there is CAD $179.99.
The battery is not included. Gallagher's data sheet lists a 15 V DC input and a 400 mA maximum output current. Its European store pairs the same unit with a 12 V 100 Ah AGM battery, sold separately. Gallagher names only its own energizers. So this is the route for a Gallagher MB or MBS owner, not for someone with a Zareba plug-in charger.
A 12 V DC charger on a deep-cycle battery
A DC charger never depends on the grid at all. Zareba says its 25-mile EDC25M-Z draws 0.113 A at 12 V, or 1.4 W. That works out to about 2.7 Ah a day. On paper, a 50 Ah battery holds about 18 days of that, and a 100 Ah battery about 37. Weeds on the wire raise the draw, so real life runs shorter. One owner on Zareba's page reports that a new group 31 deep-cycle battery lasts "3+ weeks."
Battery size matters. Zareba told one owner that a 12 V 12 Ah motorcycle battery is small for its 15-mile DC charger and to "try a higher Ah battery (at least 50Ah)." Its buying guide recommends "6-volt or 12-volt rechargeable deep cycle batteries." You will need a separate battery charger to refill it. A DC charger is also a smaller machine. Zareba rates the EDC25M-Z at 25 miles and 1 J (at 200 ohms), against 75 miles and 4 J (at 75 ohms) for the EAC75M-Z. Check the mileage and joule ratings fit your fence before you switch.
A bigger battery on the UPS
You can also hang a large battery on a UPS. A 24 V, 100 Ah bank holds about 2,400 Wh, which would run the 14 W setup for days. But a desktop UPS charger is sized for its small stock battery. Our guide to a car battery on a UPS works out three to more than seven days to refill 100 Ah, and a flooded car battery vents hydrogen while it charges. A 12 V deep-cycle battery on a DC fence charger gets you the same days of runtime with less to go wrong.
| Option | Runs from in an outage | How long | Fits |
|---|---|---|---|
| UPS on a plug-in charger | UPS battery, through an inverter | About 7 h at 14 W on a 1500 VA unit | Any plug-in charger; watch the 15 W cutoff and test on battery |
| Gallagher G58211 backup | External 12 V battery, not included | Set by the battery you add; Gallagher gives no runtime | Gallagher MB and MBS energizers only |
| 12 V DC charger | Its own deep-cycle battery, always | About 18 days per 50 Ah at 0.113 A, on paper; weeds shorten it | Fences within the DC charger's rating; needs a battery charger |
Bottom line
A UPS runs a small plug-in fence charger well. Zareba's 14 W EAC75M-Z gets about 7 hours from a 1500 VA unit. Turn off any light-load cutoff, and test the fence on battery if your UPS is simulated sine. If outages often run past a night, a 12 V DC charger on a 50 Ah or bigger deep-cycle battery is the stronger plan. Gallagher owners can add the G58211 backup instead.
What this answer does not cover
The only maker watt figure here is Zareba's 14 W for one model. The 115 W row is a ceiling, and other brands publish other numbers or none. The runtimes are estimates for new batteries. Older batteries, cold sheds and weedy fence lines all cut them. The DC battery days are arithmetic on Zareba's 0.113 A figure, not a field result. No source here says whether simulated sine affects a fence charger, so the test above is the only answer this page can give. A UPS does not make a fence charger safe to install. Zareba says to mount plug-in chargers "in a sheltered location" near the outlet and to protect them from weather, and every fence needs its own ground rod system. Keep the UPS in the same dry, sheltered spot. Nothing here replaces the charger's own manual.
Test it before you need it
With the fence connected, read the voltage at the far end with a fence tester. Switch off the breaker that feeds the UPS. Read it again, then check that the UPS is still on after 20 minutes. Note the time, and see how long the UPS lasts.
Frequently asked questions
How many watts does an electric fence charger use?
Small plug-in chargers use far less than most people guess. Zareba says its 75-mile AC charger draws 14 W while it runs. Its 25-mile battery model draws 0.113 A at 12 V, which Zareba works out as 1.4 W and 33.6 Wh a day. For its 100-mile AC model, Zareba only says it draws less than one amp. Measure your own with a plug-in meter.
How long will a UPS run a fence charger?
For a 14 W charger like the Zareba EAC75M-Z, about 2 hours on a 600 VA UPS, 5 hours on a 1000 VA unit, 7 hours on a 1500 VA unit and 16 hours 40 minutes on a 2200 VA tower. These are estimates for new batteries, and they include the few watts the UPS uses itself.
Why does my UPS turn off with only the fence charger plugged in?
It may have a light-load cutoff. APC says Back-UPS models with No-load Shutdown turn off on battery when the load is less than 15 watts, after 15 minutes. A 14 W charger sits just under that line. APC's FAQ shows how to switch the feature off. Not every model has it, so check your manual.
Does the Gallagher battery backup work with a Zareba charger?
Gallagher does not say so. Its Canadian product page lists the G58211 as compatible with MB and MBS i Series and the MBS range of Gallagher energizers. The unit fits between a Gallagher power supply and a Gallagher energizer. For a Zareba plug-in charger, a UPS or a DC charger on its own battery is the backup route.
What size battery does a 12 V fence charger need?
Zareba told one owner that a 12 V 12 Ah motorcycle battery is small for its 15-mile DC charger and to "try a higher Ah battery (at least 50Ah)." Zareba's buying guide recommends 6 V or 12 V rechargeable deep cycle batteries. Weeds touching the wire make the charger draw more, so the battery lasts less time.
Sources and further reading
- Zareba: 75 Mile AC Powered Low Impedance Charger, EAC75M-Z (specs and Q&A, 14 W answer dated October 30, 2025)
- Zareba: 100 Mile AC Powered Low Impedance Charger, EAC100M-Z (specs and Q&A, less than one amp)
- Zareba: 25 Mile Battery Operated Low Impedance Charger, EDC25M-Z (0.113 A at 12 V)
- Zareba: 15 Mile Battery Operated Low Impedance Charger, EDC15M-Z, all questions (battery size answer)
- Zareba: Find the Best Electric Fence Charger (low-impedance definition, weeds, deep cycle batteries)
- Gallagher: Battery Back Up Charger G58211, Canadian store (the US store page returned not found when checked)
- Gallagher: Data Info Sheet, part no. 582108, MB battery backup / charger (PDF)
- APC by Schneider Electric FAQ000210003: Back-UPS No-load Shutdown