How Long Will a UPS Run a Hydroponics Air Pump?

For hours, and with the smallest pumps most of a day. Hydrofarm rates its Active Aqua air pumps at 2, 3, 6 and 12 W, and a common 1500 VA UPS runs those for about 19, 17, 12 and 8 hours. Back up the air pump (and the water pump, if your system has one). Leave the grow lights off the battery.

On this page
  1. Which pump the plants need in an outage
  2. How many watts the pumps draw
  3. Worked through: an 8-site DWC on a 1500 VA UPS
  4. Runtime by pump and UPS size
  5. The 15 W trap
  6. Setting it up
  7. Battery air pumps and pumps with backup built in
  8. What this answer does not cover
  9. Frequently asked questions

A UPS runs a home hydroponics air pump for hours, and a small one for most of a day. Hydrofarm rates its Active Aqua air pumps at 2 to 12 W. A common 1500 VA UPS carries a 12 W pump for about 8 hours and a 2 W pump for about 19. Add the water pump if your system has one. Keep the grow lights off the battery.

First, the terms. Deep water culture (DWC) is a way of growing plants with their roots hanging in a tank of nutrient water. A bubble bucket is the one-plant version: a bucket, a lid with a net pot, and roots in the water below. Oregon State University Extension describes DWC as roots "submerged in a nutrient-rich water solution," kept "well-oxygenated" by "air pumps and air stones." The air pump sits outside the water and pushes air down a thin tube. The air stone on the end breaks that air into fine bubbles. A UPS (uninterruptible power supply) is a battery box that keeps its outlets live when the wall power fails.

Which pump the plants need in an outage

That depends on the system, and it is where two answers get mixed up. One says the water pump is the critical part. The other says the air pump is. Both are right, for different systems.

In DWC, the roots sit in the water all the time. What they lose in an outage is the oxygen the bubbles add. University of Missouri Extension says DWC "requires simple aeration pumps to supply additional oxygen to roots; however, the plants will not immediately wilt if pumps fail." So in DWC and bubble buckets, the air pump is the load to keep running. If your DWC also circulates water between buckets, add that pump too.

In systems that pump water over the roots, such as NFT (nutrient film technique, where a thin stream runs down a channel) or drip, it is the other way round. Missouri's guide says that "if water pumps fail, or if driplines clog, plants may immediately wilt." There, the water pump is the load that matters most.

The grow lights are the part you can drop. If they run on a timer, the plants already spend hours in the dark each day. Every watt of light on the battery comes out of the pump's runtime.

How many watts the pumps draw

Air pumps are small loads. Hydrofarm publishes watts for every model in its Active Aqua line, from the one-outlet hobby pump to the 12-outlet commercial one. Its water pumps are on the same scale.

Published ratings for Hydrofarm Active Aqua pumps (120 V, 60 Hz)
ModelTypeOutletsAir or water flowRated watts
AAPA3.2LAir pump13.2 L/min2 W
AAPA7.8LAir pump27.8 L/min3 W
AAPA15LAir pump415 L/min6 W
AAPA25LAir pump825 L/min12 W
AAPA45LCommercial air pump645 L/min20 W
AAPA70LCommercial air pump870 L/min60 W
AAPA110LCommercial air pump12110 L/min112 W (1.0 A max)
AAPW160Submersible water pumpn/a160 GPH9.5 W
AAPW250Submersible water pumpn/a250 GPH16 W
AAPW400Submersible water pumpn/a370 GPH24 W

The air pump figures come from Hydrofarm's product pages and its instruction sheets. For the AAPA110L, Hydrofarm gives "maximum amperage is 1.0A" at 120 V. That is 120 VA, so the pump fits inside even a 600 VA UPS (see VA vs watts). Other brands publish other numbers, and some publish none. A plug-in watt meter answers it in a minute; how to measure power draw shows how.

Worked through: an 8-site DWC on a 1500 VA UPS

Take a home DWC with eight sites. Suppose one Hydrofarm AAPA25L feeds all eight air stones, at 12 W. Suppose the buckets also share water, moved by an AAPW160 at 9.5 W. The pumps total 21.5 W. Both plug into the battery side of a 1500 VA UPS with two 12 V 9 Ah batteries. Those two batteries hold 216 Wh.

These figures use the model behind our UPS runtime calculator. It assumes new batteries, 88% inverter efficiency and 8 W used by the UPS itself. It also allows for lead-acid batteries giving more of their capacity at low current. Why UPS runtime is not linear covers each term.

Battery draw = (21.5 W + 8 W) / 0.88 = 33.5 W, or 1.40 A at 24 V
Runtime = 20 h x (9 Ah / (1.40 A x 20 h))^1.25 = about 4.85 hours, or 4 h 50 min

So if the power fails at 10 pm, both pumps run until about 3 am. Now suppose the buckets do not share water, and only the air pump is on the battery. The same sum at 12 W gives about 7 h 55 min. Cutting the water pump buys three more hours of air.

Our analysis: the UPS is the biggest load on the battery

With a 2 W pump, the UPS's own 8 W running cost is four times the pump. Then the inverter loses more turning battery power into 120 V. Less than a fifth of what leaves the battery reaches the pump. That is why the 2 W pump does not run six times as long as the 12 W one: about 18 h 45 min against 7 h 55 min on the same 1500 VA unit. Moving the 12 W pump from a 1500 VA to a 2200 VA unit gains as much: it also comes out at about 18 h 45 min.

Runtime by pump and UPS size

Here is the same math across common UPS sizes. Each assumes the pump runs nonstop, which air pumps do.

Estimated runtime by load and UPS class (new batteries, 88% efficiency, 8 W UPS overhead)
Load600 VA (1 x 12 V 7 Ah)1000 VA (2 x 12 V 7 Ah)1500 VA (2 x 12 V 9 Ah)2200 VA (2 x 12 V 18 Ah)
2 W (AAPA3.2L)about 5 h 45 minabout 13 h 40 minabout 18 h 45 minabout 38 h
3 W (AAPA7.8L)about 5 h 5 minabout 12 h 10 minabout 16 h 40 minabout 34 h 35 min
6 W (AAPA15L)about 3 h 45 minabout 9 habout 12 h 20 minabout 27 h 10 min
12 W (AAPA25L)about 2 h 25 minabout 5 h 45 minabout 7 h 55 minabout 18 h 45 min
21.5 W (AAPA25L + AAPW160)about 1 h 30 minabout 3 h 35 minabout 4 h 50 minabout 11 h 35 min
112 W (AAPA110L)about 15 minabout 35 minabout 50 minabout 2 h

None of these loads comes close to overloading the UPS. The question is only how long the battery lasts. For a commercial pump like the AAPA110L, a desktop UPS is a bridge of under an hour, not an outage plan.

The 15 W trap

Every home pump in the table draws less than 15 W. That matters on some APC units. APC says its "Back-UPS products with No-load Shutdown functionality enabled will shut down while operating on battery power when the attached load is less than 15 watts." It happens after 15 minutes on battery.

So a 6 W pump could stop a quarter hour into the outage, with half a day of battery left. APC's FAQ shows how to switch the feature off, and not every Back-UPS has it, so check your manual. Then test it. With only the pump plugged in, switch off the breaker that feeds the UPS and wait 20 minutes. If the UPS goes dark, see why a UPS shuts off during an outage. The same trap catches a 14 W electric fence charger.

Setting it up

  1. Split the outlets. Most UPS units have two kinds. Battery outlets stay live in an outage. Surge-only outlets go dead with the wall. Put the air pump, and any water pump, on battery. Put the lights, fans and any heater on surge-only. UPS outlets and plugs explains the labels.
  2. Mount the pump above the water. Hydrofarm's instructions say to keep the pump "above the water level of the reservoir," or water may back-flow "through the air tube and damaging the pump." They also recommend check valves. An outage is when this happens, because the pump stops pushing air.
  3. Keep the UPS dry. Set it off the floor and away from the reservoir, where a spill or a leak cannot reach it. Where to place a UPS covers heat and airflow.
  4. Prefer pure sine output. The small Active Aqua pumps use a rubber diaphragm, and Hydrofarm describes the commercial ones as an "electrical magnetic air compressor." Hydrofarm says nothing about UPS waveform. Our aquarium guide covers why pumps like these can buzz and run warm on a stepped wave. A pure sine UPS removes the question.
  5. Test it twice a year. Unplug the UPS with the real pumps running. Note how long it lasts, and check that the bubbles keep coming.

Battery air pumps and pumps with backup built in

A UPS is not the only way to keep air in the water. Two kinds of pump carry their own backup.

D-cell backup pumps. Hydra Aquatics says its HydraResQ "automatically switches to battery operation during power outages." It takes two D cells and gives an "average battery service" of 30 hours. Its output is 0.7 L/min. That is about a fifth of the 3.2 L/min from Hydrofarm's smallest AC pump, the 2 W AAPA3.2L. One of these suits a single bucket. Eight sites would need several.

Pumps with a battery inside. Reef Builders reports that Amtra's Air System 360 UPS can stay off in normal use and "automatically switch on as soon as there is a loss of main power." Amtra claims "16 hours of life-saving time." Reef Builders gives no wattage or airflow, so check the pump's own sheet against your system.

Backup options for a DWC air pump, as covered above
OptionHow longAirWatch for
UPS on a 12 W AAPA25LAbout 7 h 55 min on a 1500 VA unit25 L/min, 8 outletsThe 15 W cutoff on some APC units
UPS on a 2 W AAPA3.2LAbout 18 h 45 min on a 1500 VA unit3.2 L/min, 1 outletThe 15 W cutoff on some APC units
HydraResQ, 2 D cells30 hours average, by the maker0.7 L/minFar less air than an AC pump
Amtra Air System 360 UPS16 hours, by the makerNot given in the sourceCheck its sheet before relying on it

For outages longer than a day, a power station holds more energy than a desktop UPS. UPS vs portable power station sets out the trade.

Bottom line

Put the air pump on a UPS battery outlet and the lights on surge-only. A 1500 VA unit runs a 2 to 12 W Active Aqua pump for about 8 to 19 hours. Add a circulation pump only if your system needs it, since it cuts the runtime by a third or more. Turn off any light-load cutoff, fit check valves, and keep a D-cell pump as a second layer for long outages.

What this answer does not cover

We found no extension or university source that says how many hours roots last without aeration. Missouri's guide says only that DWC plants "will not immediately wilt," so this page gives no root survival time. The pump watts are Hydrofarm's ratings for its own models; other brands need their own label or a meter. The runtimes are estimates for new batteries. Older batteries and a UPS that uses more than 8 W itself give less. The HydraResQ and Amtra figures are the makers' claims, not ours. Commercial setups with several large pumps, chillers or dosing gear need a generator plan, not a desktop UPS. The same split between air and water pumps runs through our septic aerator guide, where a UPS carries the air pump but not the effluent pump. Nothing here replaces the pump's own instructions.

Frequently asked questions

How many watts does a hydroponic air pump use?

Less than most people guess. Hydrofarm's Active Aqua line runs 2 W for the one-outlet AAPA3.2L, 3 W for the AAPA7.8L, 6 W for the AAPA15L and 12 W for the eight-outlet AAPA25L. Its commercial pumps are larger: 20 W for the AAPA45L, 60 W for the AAPA70L and 112 W for the AAPA110L. Other brands differ, so read the label or measure with a plug-in meter.

What happens to DWC plants when the power goes out?

The air pump stops, so the roots stop getting fresh oxygen from the air stone. University of Missouri Extension says DWC plants "will not immediately wilt if pumps fail," which is why DWC forgives a short outage better than NFT or drip systems. No extension source we found puts a number of hours on it, so keep the pump running if you can.

Can I run a hydroponic air pump on a power bank?

Not a standard AC pump like the Active Aqua line. Those are 120 V, 60 Hz pumps and need an AC outlet, which is what a UPS or a power station's inverter provides. A USB power bank can run a pump made for 5 V USB. Check the pump's label for its input before you buy a battery for it.

Should I use a check valve on my air line?

Yes. Hydrofarm's instructions say to mount the pump above the water level and recommend check valves "to prevent water backflow into air pump." An outage is when that matters, because the pump stops pushing air and water can creep back down the tube. Fit one on each line if the pump sits low.

Is a portable power station better than a UPS for hydroponics?

For long outages, often yes, because it holds more energy. A UPS switches over the instant the power fails, so the pump never stops. Not every power station is built to sit plugged in and switch over like that, so read the maker's notes. Our UPS vs portable power station guide compares them.

Sources and further reading

  1. Hydrofarm: Active Aqua Air Pump, 8 Outlets, 12W, 25 L/min (AAPA25L family page: AAPA3.2L 2 W, AAPA7.8L 3 W, AAPA15L 6 W)
  2. Hydrofarm: Instructions, Air Pumps AAPA3.2L, AAPA7.8L, AAPA15L, AAPA25L (specifications, above water level, check valves)
  3. Hydrofarm: Active Aqua Commercial Air Pump, 12 Outlets, 112W, 110 L/min (AAPA110L, maximum 1.0 A)
  4. Hydrofarm: Active Aqua Commercial Air Pump, AAPA45L (20 W) and AAPA70L (60 W)
  5. Hydrofarm: Instructions, Active Aqua commercial air compressors AAPA45L, AAPA70L, AAPA110L
  6. Hydrofarm: Active Aqua Submersible Water Pump, 160 GPH (9.5 W), 250 GPH (16 W) and 370 GPH (24 W)
  7. Cabrera-Garcia, Milhollin and Ernst, University of Missouri Extension: Controlled Environment Agriculture: Hydroponic Farming (G6986, revised July 2024)
  8. Nelson, Langellotto and Nackley, Oregon State University Extension: Hydro hints: Deep water culture (EM 9455)
  9. Reef Builders: Amtra air pump comes with built-in battery backup (Air System 360 UPS, December 2021)
  10. Hydra Aquatics HydraResQ Emergency Backup and Portable Air Pump (2 D cells, 30 hours, 0.7 L/min)
  11. APC by Schneider Electric FAQ000210003: Back-UPS No-load Shutdown