The CP1500PFCLCD is the safer pick for any modern desktop PC. The CP1500AVRLCD is the right pick when nothing on its battery outlets has an active PFC power supply. Everything else about the two is close: they share the same batteries, the same box size and the same warranty, and they land on nearly the same runtime once you compare them at the same load.
Two terms the choice turns on
Simulated sine wave is what the CP1500AVRLCD makes on battery. Wall power is a smooth curve, while a simulated (or stepped) sine wave jumps straight up to a set voltage, holds it flat, drops to zero, then jumps negative. It has the right average voltage but the wrong shape. The CP1500PFCLCD makes a smooth sine wave on battery instead. Our guide to pure sine vs simulated sine shows both shapes.
Active PFC (active power factor correction) is a circuit at the input of a power supply. It makes the supply draw current smoothly, in step with the voltage, instead of in sharp spikes. It does that with a control loop that expects a sine wave coming in, so when it is fed a stepped wave, some supplies shut off, buzz, or trip the UPS into overload. Not all do, and the risk climbs with load. The details are in our page on active PFC power supplies.
That is why CyberPower's own datasheet says the PFCLCD is for "desktop computers, workstations, and networking devices requiring active PFC power source compatibility." The PFCLCD manual adds that the US ENERGY STAR program for computers (version 7.1) requires active PFC on every power supply over 100 watts.
The spec sheets side by side
These figures come from CyberPower's datasheets. The PFCLCD sheet is for the CP1500PFCLCDTAA, the version built for government buyers. Its core ratings match the retail CP1500PFCLCD manual: 1500 VA / 1000 W, sine wave on battery, 1445 joules and an 8 hour recharge.
| Spec | CP1500PFCLCD | CP1500AVRLCD | CP1500AVRLCD3 |
|---|---|---|---|
| Rating | 1500 VA / 1000 W | 1500 VA / 900 W | 1500 VA / 900 W |
| Topology | Line-interactive | Line-interactive | Line-interactive |
| Waveform on battery | Sine wave | Simulated sine wave | Simulated sine wave |
| Batteries | 2 x 12 V / 9 Ah | 2 x 12 V / 9 Ah | 2 x 12 V / 9 Ah |
| Runtime, half / full load | 10 / 2.5 min | 12 / 3 min | 12 / 3 min |
| Typical transfer time | 4 ms | 4 ms | 4 ms |
| Typical recharge time | 8 hours | 8 hours | 8 hours |
| AVR | Single boost, +11.5% | Single boost, +10% | Single boost |
| Outlets (battery + surge only) | 6 + 6 | 6 + 6 | 6 + 6 |
| Surge rating | 1445 J | 1500 J | 1500 J |
| USB charge ports | Type-A + Type-C, 3.1 A shared | None | Type-A 2.4 A + Type-C 15 W |
| Network card slot | Yes (RMCARD205) | No | No |
| Warranty / equipment guarantee | 3 years / $500,000 | 3 years / $500,000 | 3 years / $500,000 |
The 4 ms transfer time is the gap between wall power failing and the battery taking over, and a desktop power supply rides through it on its own stored charge. See UPS transfer time for why 4 ms is normal for this class. AVR (automatic voltage regulation) lifts low wall voltage without touching the battery, and both units have a single boost step, so they handle sags alike. Our page on AVR explains how it works.
The runtime confusion, settled
At a glance the cheaper AVRLCD seems to run longer: 12 minutes at half load against 10. That reading is wrong. "Half load" means half of each unit's own watt rating: 450 W for the 900 W AVRLCD and 500 W for the 1000 W PFCLCD. The two sheets are timing different loads.
The batteries are the same: two 12 V / 9 Ah blocks, about 216 Wh on the label. So the question is what each unit gets out of them at one shared load. Each sheet gives two points. On both sheets, doubling the load cuts the runtime to a quarter (12 to 3 minutes, and 10 to 2.5). Using that same slope to move each unit onto the other's half load gives this:
| Load | CP1500AVRLCD | CP1500PFCLCD |
|---|---|---|
| 450 W | 12 min (published) | about 12.3 min (scaled) |
| 500 W | about 9.7 min (scaled) | 10 min (published) |
| 900 W | 3 min (published) | about 3.1 min (scaled) |
The gap is a few percent either way, too small to choose on. Treat runtime as a tie. Real runtime falls as the batteries age, so use the runtime guide for your own load.
Our analysis: the extra 100 W is the real capacity difference
Same batteries means the same minutes at the same load. What the PFCLCD adds is headroom: it can carry 1000 W before overload, while the AVRLCD stops at 900 W. For a heavy PC that is the part of the capacity gap that matters, not the runtime line.
Worked example: one gaming PC, both units
Take a gaming PC with an 850 W, 80 PLUS Gold power supply. Suppose it draws about 450 W at the wall while gaming, and a 40 W monitor brings the total on the battery outlets to 490 W.
- Check for active PFC. The 80 PLUS program requires a power factor of at least 0.9 at full load. In practice only active PFC supplies reach that, so this PC has active PFC.
- Apply the waveform rule. An active PFC supply on stepped output is the case CyberPower built the PFCLCD for. That rules the AVRLCD out before sizing even starts.
- Check capacity anyway. Our gaming PC sizing guide plans gaming loads at 70% of the watt rating, because GPU spikes are hidden from a watt meter. That is 700 W on the PFCLCD and 630 W on the AVRLCD. 490 W fits both, so capacity does not decide it; the waveform does.
- Read the runtime. At 490 W, the PFCLCD sits just under its 500 W half load point, so expect a little over 10 minutes with fresh batteries. That is time to save and shut down, not to keep playing.
Now swap the load for a fiber ONT, a router and a mesh node, about 40 W in all, each on a small adapter. None of them have active PFC to upset, so here the AVRLCD is fine and the PFCLCD buys nothing but a smoother wave that no device needs.
When the CP1500AVRLCD is enough
Simulated sine is fine when nothing on the battery outlets has active PFC. In practice that means:
- Network gear on small adapters: modems, routers, ONTs, switches and VoIP adapters. See UPS for modem and router.
- Laptops on their chargers. The laptop's own battery carries it through anything odd in the wave.
- Older PCs with passive PFC or none. A red 115/230 V switch on the back of the power supply usually marks one of these.
The AVRLCD also suits a home with frequent sags but few blackouts. Its AVR handles the sags the same way the PFCLCD's does, and the waveform never comes into play on wall power.
If you already own an AVRLCD and an active PFC PC, do not replace it on faith. Test it: put the PC under its usual heavy load, pull the UPS plug from the wall, and watch for a minute. The full steps are in the active PFC guide. If the PC shuts off, the fix is a sine wave unit. Our page on a UPS that shuts off during an outage covers the other causes first, such as a worn battery.
What changed in the CP1500AVRLCD3
Stores now list the CP1500AVRLCD3 next to, or in place of, the original. Its 2024 datasheet keeps every rating that matters to this choice: it is still 1500 VA / 900 W, still simulated sine on battery, and still 12 minutes at half load and 3 at full. Transfer time (4 ms), recharge time (8 hours), batteries, outlets and warranty are unchanged. The changes are:
- Two USB charge ports: one USB-A at 2.4 A and one USB-C at 15 W, 20 W in total.
- A smaller, lighter box: 10.2 in tall and 23.8 lb, against 11 in and 25.0 lb.
- A new battery cartridge number: RB1290X2E, where the original lists RB1290X2 or RB1280X2A depending on serial number.
Nothing on that list touches the waveform, so the 3 suffix does not make the AVRLCD safe for active PFC loads. Its sheet now says "sine wave" for the on-AC waveform, but that only describes wall power passing through. The on-battery line still reads simulated sine.
Decision table
| What is on the battery outlets | Pick | Why |
|---|---|---|
| Desktop or gaming PC with an 80 PLUS badge or a 100-240 V input and no switch | CP1500PFCLCD | Active PFC; CyberPower names the PFCLCD for this load |
| Load between 630 and 700 W (gaming, 70% margin) | CP1500PFCLCD | Only the 1000 W rating leaves the margin |
| Modem, router, ONT, switch on small adapters | CP1500AVRLCD (or smaller) | No active PFC to upset |
| Laptop on its charger | CP1500AVRLCD | The laptop battery rides through the wave |
| Older PC with a 115/230 V switch | CP1500AVRLCD | Passive or no PFC |
| You want the longest runtime | Either | Same batteries; equal at equal load |
| You want USB charge ports | CP1500PFCLCD or CP1500AVRLCD3 | The original AVRLCD has none |
| You want a network card later | CP1500PFCLCD | Only it has the RMCARD205 slot |
Bottom line
Any active PFC computer belongs on the CP1500PFCLCD. Save the CP1500AVRLCD (or the AVRLCD3) for network gear, laptops and older PCs. Do not pick either one for runtime: at the same load they run for the same time.
What this comparison does not cover
The runtime figures are CyberPower's own, for new, fully charged batteries at room temperature. The equal-load numbers above are our arithmetic from two points on each sheet, not a measured curve, and aging batteries run shorter on both. This page also does not judge the waveform quality of either unit beyond what the sheets state, and it does not cover motor loads such as sump pumps or furnace blowers, which have their own rules. CyberPower's manual says to keep the load below 80% of the rated capacity and to keep laser printers, space heaters and sump pumps off the battery outlets. Those rules apply to both units.
For how these two fit among CyberPower's other series, see the CyberPower lineup guide. To weigh them against APC's Back-UPS Pro, see APC vs CyberPower.
Frequently asked questions
Can I use a CP1500AVRLCD with a gaming PC?
Not as a safe default. Gaming PCs use active PFC power supplies, and those are the loads most likely to shut off on stepped output, more so at high load. The AVRLCD is also capped at 900 W, so a 70% gaming margin is 630 W. Buy the CP1500PFCLCD, or test an AVRLCD you already own under a real gaming load before trusting it.
Is the CP1500AVRLCD3 pure sine wave?
No. CyberPower's CP1500AVRLCD3 datasheet lists the on-battery waveform as simulated sine wave, the same as the original CP1500AVRLCD. It also lists the on-AC waveform as sine wave, which only means it passes wall power through. The 3 version mainly adds two USB charge ports.
Why does the CP1500AVRLCD show more runtime than the CP1500PFCLCD?
Because the sheets measure at different loads. Half load means half the watt rating: 450 W for the 900 W AVRLCD and 500 W for the 1000 W PFCLCD. Both have the same two 12 V / 9 Ah batteries. At the same load, the runtimes come out within a few percent of each other.
Does the CP1500PFCLCD use the same battery as the CP1500AVRLCD?
Both take two 12 V / 9 Ah sealed lead-acid batteries in one cartridge. CyberPower lists RB1290X2 for both (with an alternate cartridge for some serial number ranges), and RB1290X2E for the CP1500AVRLCD3. Check the cartridge for your serial number before ordering.
Is the CP1500PFCLCD worth it for a router and modem only?
Not for the waveform. Routers, modems and ONTs run from small adapters that do not care about stepped output. Either unit is far bigger than that load needs, so a smaller unit is the better buy. If you also plan to add a desktop later, the PFCLCD saves buying twice.
Sources and further reading
- CyberPower: CP1500PFCLCDTAA PFC Sinewave UPS datasheet (2023)
- CyberPower: CP1350PFCLCD / CP1500PFCLCD user's manual
- CyberPower: CP1500AVRLCD Intelligent LCD UPS datasheet (2023)
- CyberPower: CP1500AVRLCD3 Intelligent LCD UPS datasheet (2024)
- 80 Plus: certification requirements (efficiency at 20, 50 and 100% load; power factor 0.9 or greater at 100% load)