- Two terms the answer depends on
- How much hold-up a computer power supply has
- Maker-rated switchover time, model by model
- Measured switchover: what testing found
- The DELTA 3 Plus does have a UPS mode
- Worked example: one gaming PC, two power stations
- The shutdown signal most power stations lack
- Decision table
- What this comparison does not cover
- Frequently asked questions
A power station can stand in for a UPS on a computer if its switchover is rated at 10 ms or less. Four models meet that on their maker pages: the EcoFlow DELTA 3, DELTA 3 Plus and RIVER 3 Plus, and the Anker SOLIX C2000 Gen 2. Seven more are rated at 20 ms or "under 20 ms". A desktop power supply is not required to bridge a gap that long at full load.
The second gap is the shutdown signal. A UPS tells the computer when its battery is running low. Most power stations do not, so a long outage still ends with the PC switching off hard.
Two terms the answer depends on
Switchover time is the gap between wall power failing and the power station's own inverter feeding the outlets. Power station makers call this UPS mode or EPS mode. On a UPS, the same gap is called transfer time. During the gap, the outlets carry no power at all.
Hold-up time is how long a computer's power supply keeps its outputs steady after its input power disappears. It runs on the energy stored in its large input capacitor. If the switchover gap is shorter than the hold-up time, the PC never notices. If it is longer, the PC reboots or switches off.
So the whole question is one comparison: switchover time on one side, hold-up time on the other.
How much hold-up a computer power supply has
Intel's ATX12V Power Supply Design Guide, version 2.2, says a supply "should maintain output regulation" for at least 17 ms after losing input power, at maximum continuous load. The same guide asks for at least 16 ms from AC loss to the PWR_OK signal dropping. PWR_OK is the "power good" line that tells the motherboard the supply is healthy.
Newer supplies have less. Seasonic's comparison of the two current standards puts ATX 3.0 at 17 ms at full load. ATX 3.1 lowers that to 12 ms at full load, with 17 ms at 80% load only recommended.
Those two ATX 3.1 numbers show that hold-up grows as load falls. So the safe figure to plan around is the full-load one: 12 ms for an ATX 3.1 supply, 17 ms for an older ATX12V design.
A desktop UPS sits well inside both. APC's data sheets give the BR1500MS2 8 ms typical, 10 ms maximum, and the SMT1500C 6 ms typical, 10 ms maximum.
Maker-rated switchover time, model by model
Every figure below comes from the maker's own product page or blog. A "<" or "under" figure is a ceiling: the maker promises no more than that, not exactly that. A model is listed only if a maker page states a number.
| Model | Maker's wording | Inside 12 ms (ATX 3.1, full load)? | Inside 17 ms (ATX12V)? |
|---|---|---|---|
| APC SMT1500C (UPS, for reference) | 6 ms typical, 10 ms max | Yes | Yes |
| APC BR1500MS2 (UPS, for reference) | 8 ms typical, 10 ms max | Yes | Yes |
| EcoFlow DELTA 3 | UPS <10ms | Yes | Yes |
| EcoFlow DELTA 3 Plus | UPS <10ms | Yes | Yes |
| EcoFlow RIVER 3 Plus | less than 10 milliseconds | Yes | Yes |
| Anker SOLIX C2000 Gen 2 | 10 ms | Yes | Yes |
| Anker SOLIX C1000X | <20ms | Not promised | Not promised |
| Anker SOLIX F2000 (PowerHouse 767) | under 20ms | Not promised | Not promised |
| EcoFlow RIVER 3 | UPS <20 ms | Not promised | Not promised |
| Jackery Explorer 1000 v2 | under 20 milliseconds | Not promised | Not promised |
| Jackery Explorer 1000 Plus | less than 20ms (EPS) | Not promised | Not promised |
| BLUETTI AC180 | just 20ms | No | No |
| BLUETTI AC200L | 20ms | No | No |
The split is simple. A rating of 10 ms or less sits under both hold-up figures. A flat 20 ms is longer than both. "Under 20 ms" could land anywhere below 20, so it promises neither.
Two notes on the pages themselves. The EcoFlow RIVER 3 page used here is the Canadian one, since the US store no longer lists the base model. EcoFlow's UK page lists a separate "RIVER 3 UPS" version at under 10 ms. Jackery's US page for the Explorer 1000 Plus gives no figure, so the number comes from its UK page.
Measured switchover: what testing found
A maker's rating is a claim. StorageReview measured several units with a Quarch power analysis module, which logs the output every 125 microseconds. They cut wall power to each station while it ran a workstation, and timed the gap.
| Unit | Listed | Measured |
|---|---|---|
| Eaton 5PX G2 (UPS) | less than 10 ms | 8.6 ms |
| EcoFlow DELTA 3 Plus | 10 ms | just over 8 ms |
| Jackery Explorer 2000 Plus | none listed | 8.7 ms |
| BLUETTI AC60 | less than 20 ms | 13.8 ms |
| BLUETTI AC70 | less than 20 ms | about 14 ms |
| Ugreen PowerRoam 1200 | less than 20 ms | 15.3 ms |
| Anker SOLIX F2000 | 20 ms | 27.4 ms |
| EcoFlow Delta 2 | less than 30 ms (EcoFlow) | 38.5 ms |
Six units came in under their listed figure. Two did not. The Anker F2000 took 27.4 ms against a listed 20 ms, and the Delta 2 took 38.5 ms against EcoFlow's "less than 30ms". StorageReview called 38.5 ms "really pushing it for computer power supplies".
Every unit kept the test PC running. That result does not carry over to most desktops. The workstation was idle, and StorageReview wrote that its supply "is incredibly overbuilt and managed to stay online through an almost 40ms transfer time". They advised testing your own devices first for stations in the 13 to 16 ms range.
Our analysis: read a 20 ms rating as "test it"
Every unit that measured inside 12 ms was either rated at 10 ms or less or had no rating. The units listed at 20 ms or under 20 ms measured 13.8 to 27.4 ms. That is above 12 ms every time, and above 17 ms once. A 20 ms station may run your PC fine, but the spec sheet cannot tell you that. Only a test at your real load can.
The DELTA 3 Plus does have a UPS mode
One review site gets this model wrong. A backuppowerhub review says the DELTA 3 Plus "lacks a dedicated UPS (Uninterruptible Power Supply) function with a fast switchover time". EcoFlow's own DELTA 3 Plus page lists "UPS <10ms" in its specifications. It also calls it "a 10 ms UPS" in the feature text. StorageReview measured just over 8 ms on the unit it tested. That matches the 10 ms maximum on APC's desktop UPS sheets.
Worked example: one gaming PC, two power stations
Take a gaming PC with a 750 W power supply carrying the ATX 3.1 label. Suppose it pulls close to 750 W from the supply in a heavy game. Here is how two stations compare for it, using only the published figures.
- Find the hold-up to plan around. Near full load, ATX 3.1 requires 12 ms. The 17 ms figure is only recommended, and only at 80% load, so it does not apply here.
- Check a Jackery Explorer 1000 v2. Jackery rates it "under 20 milliseconds". That ceiling is 8 ms past the 12 ms requirement. The PC may ride through if its supply beats the minimum, but nothing on paper says it will.
- Check an EcoFlow DELTA 3 Plus. EcoFlow rates it under 10 ms. That leaves at least 2 ms of margin on the 12 ms requirement. StorageReview measured just over 8 ms on one unit, which leaves about 4 ms.
- Plan the end of the outage. Neither station's page says the PC will be told to shut down, unless the DELTA 3's HID mode is set up (next section). Without that, the PC runs until the station's battery is empty, then switches off hard.
For this PC, the DELTA 3 Plus is the station that fits on paper. The Jackery is a candidate only after a pull-the-plug test at gaming load. The same PC at a light office load has more hold-up, so a 20 ms station has a better chance there. But that is still something to test, not to assume.
The shutdown signal most power stations lack
A UPS does two jobs. It bridges the gap, and it tells the computer when to shut down. Almost every desktop UPS connects by USB and shows up as a standard HID power device. Windows, macOS, Linux and NAS systems then shut down on their own when the battery runs low. APC's SMT1500C page, for one, describes "graceful shutdown" over serial or USB with PowerChute. Our UPS software overview covers how each system handles it.
Of the eleven power station pages above, only EcoFlow's DELTA 3 series page describes this. A footnote says to install the EcoFlow PowerManager app, run the NUT server software on the NAS, connect the DELTA 3 Plus and "activate HID support". NUT is Network UPS Tools, the open-source program most NAS systems use to watch a UPS; see our NUT guide. The footnote also says "the formal launch version will come later in December". So check that your firmware and app support it before you count on it.
The other pages list USB ports as charging outputs only. A power station without a shutdown link can carry a PC far longer than a desktop UPS. But when it runs dry, the PC loses power mid-write. For a NAS or a server, that is the event a UPS exists to prevent.
Decision table
| Your situation | What fits | Why |
|---|---|---|
| Desktop run near full load, ATX 3.1 supply | Station rated 10 ms or less, or a UPS | ATX 3.1 requires only 12 ms at full load |
| Older ATX12V supply | Station rated 10 ms or less, or a UPS | The guide's 17 ms is below a flat 20 ms rating, and "under 20 ms" does not promise to stay under it |
| You already own a 20 ms class station | Use it only after a pull-the-plug test at your heaviest load | StorageReview measured 13.8 to 27.4 ms on that class |
| PC, NAS or server that must shut down unattended | A UPS, or a DELTA 3 series station with its HID mode tested | Only that maker page describes a shutdown link |
| Hours of runtime for a light PC load | Power station with a fast rating | Its battery is far larger than a desktop UPS's; see UPS vs portable power station |
Bottom line
For a computer, buy a station rated at 10 ms or less, or keep a real UPS. Treat a 20 ms rating as a reason to test, not a guarantee. If the PC must shut down by itself, only a UPS or a tested HID link does that job.
What this comparison does not cover
These are the makers' ratings and one lab's measurements of single units. They do not tell you the hold-up time of your own power supply. The ATX figures are minimums, and a given supply may hold longer. The ATX figures apply to desktop supplies. A laptop runs on its own battery, so switchover does not matter to it.
The ratings do not say at what load they were measured, and StorageReview tested at idle. This page does not compare runtime, inverter output limits, or how long a lithium battery lasts when held at full charge. It also does not cover monitors, network gear and external drives on the same outlets, which have their own supplies and their own hold-up. If your PC has to stay up, the test that settles it is simple. Run your heaviest real load and pull the station's wall plug several times. For more on what a power station does and does not replace, see UPS vs portable power station. For how a power supply's front end reacts to the gap, see active PFC power supplies.
Frequently asked questions
Is 20 ms fast enough for a gaming PC?
Not on paper. A gaming PC can run its power supply near full load, and ATX 3.1 only requires 12 ms of hold-up there. A 20 ms switchover is longer than that. Many supplies hold longer than the minimum, so the PC may survive, but only a pull-the-plug test at gaming load tells you. A station rated 10 ms or less, or a real UPS, removes the guesswork.
What is the difference between UPS mode and EPS mode on a power station?
Both names describe the station switching its outlets to its own battery when wall power fails. What matters is the switchover figure, not the name. Jackery calls it EPS on its Explorer 1000 Plus page and lists it as less than 20 ms.
Does the EcoFlow DELTA 3 Plus have a UPS function?
Yes. EcoFlow's DELTA 3 Plus page lists "UPS <10ms" in its specifications, and StorageReview measured just over 8 ms on the unit it tested. A backuppowerhub review saying the DELTA 3 Plus lacks a UPS function with a fast switchover does not match EcoFlow's own page.
Can a power station shut down my computer automatically?
Usually not. A UPS shows up on the computer as a USB battery (HID) device, and the computer shuts down when the battery runs low. Most power station pages describe no such link. EcoFlow's DELTA 3 series page describes NAS support through its PowerManager app and NUT with HID turned on, so test that before you rely on it.
Why does my PC stay on during a test but reboot in a real outage?
Hold-up time shrinks as load grows. A test at idle leaves a lot of margin, while the same switchover at full load may not. StorageReview's test PC was idle and had what they called an overbuilt power supply. It stayed on through almost 40 ms, which most desktops are not built to do.
Sources and further reading
- Intel: ATX12V Power Supply Design Guide, version 2.2 (section 3.2.11 hold-up 17 ms; Table 15, AC loss to PWR_OK 16 ms or more), xDevs.com mirror
- Seasonic: Differences between ATX 3.0 and ATX 3.1 standards (hold-up 17 ms at full load vs 12 ms at full load, 17 ms at 80% recommended)
- APC by Schneider Electric: BR1500MS2 product data sheet (8 ms typical, 10 ms maximum)
- APC by Schneider Electric: SMT1500C product data sheet (6 ms typical, 10 ms maximum)
- EcoFlow: DELTA 3 Plus product page (UPS <10ms; NAS and HID footnote)
- EcoFlow: DELTA 3 product page (UPS <10ms)
- EcoFlow Canada: RIVER 3 product page (UPS <20 ms)
- EcoFlow: How to use a portable power station as a UPS (RIVER 3 Plus, less than 10 milliseconds)
- Anker SOLIX: C1000X product page (UPS switch time <20ms)
- Anker SOLIX: C2000 Gen 2 product page (UPS 10 ms)
- Anker SOLIX: F2000 (PowerHouse 767) page (switchover time under 20ms)
- BLUETTI: AC180 page (switches over in just 20ms)
- BLUETTI: AC200L page (UPS in 20ms)
- Jackery: Explorer 1000 v2 product page (under 20 milliseconds)
- Jackery UK: Explorer 1000 Plus product page (EPS, less than 20ms)
- StorageReview (Kevin OBrien, October 27, 2023): Portable power stations actually work pretty well as a UPS
- StorageReview (Dylan Dougherty, January 2, 2025): EcoFlow DELTA 3 Plus review
- backuppowerhub: EcoFlow DELTA 3 Plus review (claim corrected on this page)